For information on the components that can be connected via DRIVE-CLiQ (setup,
connection, configuration, etc.) see
3.4

PROFIBUS DP interface (SIMOTION D410 DP only)

SIMOTION D410 DP provides one interface to connect to PROFIBUS DP. The interface can
be run asynchronously or isochronously, equidistant.
A baud rate of up to 12 Mbps can be set for the PROFIBUS DP interface.
SIMOTION D410 includes master and I-slave functionality.
Note
If a SIMOTION D410 DP is operated as a passive PROFIBUS I-slave, the display,
measuring functions, and controller optimization engineering functions will be very slow. If
possible, use the "active I-slave" setting for local commissioning (which does mean that an
equidistance is no longer possible) and for complete commissioning, switch to "passive I-
slave".
Interface features
Table 3- 8
Features
Connector type
Cable type
Maximum cable length
Maximum data rate
SIMOTION D410
Manual, 02/2012
SINAMICS S120 Control Units and Additional System Components
SINAMICS S120 for AC Drives
SINAMICS S120
Commissioning Manual
SINAMICS S120 Booksize Power Units
SINAMICS S120 Safety Integrated
TM15/TM17 High Feature SIMOTION Terminal Modules
SIMOTION Terminal Modules TM15 / TM17
Interface X21
3.4 PROFIBUS DP interface (SIMOTION D410 DP only)
Manual
Manual
Function Manual
Manual
Type
9-pin SUB-D socket
PROFIBUS cable
100 m at 12 Mbps
12 Mbps
Manual
Commissioning Manual
Interfaces