YASKAWA FSDrive-MV1000 Parameter Manual page 21

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

No.
Name
(Addr.)
A2-01 to
A2-32
User Parameters 1
(106 to
to 32
125H)
User Parameter
A2-33
Automatic
(126H)
Selection
A3-01 to
A3-32
Trace Data 01 to 32
(3010H to
Selection
302FH)
A3-33
High-Speed Trace
(3030H)
Sampling Time
A3-34
Low-Speed Trace
(3031H)
Sampling Time
Number of Data
A3-35
after High-Speed-
(3032H)
Trace Fault
Detection
Number of Data
A3-36
after Low-Speed-
(3033H)
Trace Fault
Detection
A3-37
Trace Stop
(3034H)
Selection
<3> Parameter setting value is not reset to the default value when the drive is initialized (A1-03 = 1110/2220).
<10> Default setting is determined by the control mode (A1-02).
YASKAWA ELECTRIC EZZ010930 FSDrive-MV1000 Parameter Guide
A2: User Parameters
All Modes
Parameters that were recently edited are listed here. The user can also
select parameters to appear here for quick access.
All Modes
0: Parameters A2-01 through A2-32 are reserved for the user to create a
list of User Parameters.
1: Save history of recently viewed parameters. Recently edited parameters
will be saved to A2-17 through A2-32 for quick access.
A3: Trace Data
All Modes
Sets the numbers of the monitor contents to be registered as the trace data.
A maximum of 32 contents can be set.
Note: 1. Set the desired monitor parameter in the digits available in U -
. For example, enter "103" for U1-03 (output current).
2. Set 000 if the parameter is not to be used.
3. When a CPF00, CPF01, CPF06, Uv1, oFA00, oFb00 or oFC00
fault occurs, no fault trace is performed.
All Modes
Sets the sampling time for high-speed tracing in 0.001 s units. Note,
however, that if 0.000 s is set, the setting made will actually be 0.00025 s
(250 μs).
Note: 1. The maximum number of samplings for high-speed tracing is
4000 per content.
2. When a CPF00, CPF01, CPF06, Uv1, oFA00, oFb00 or oFC00
fault occurs, no fault trace is performed.
All Modes
Sets the sampling time for low-speed tracing in 0.01s units.
Note: 1. The maximum number of samplings for low-speed tracing is 500
per content.
2. When a CPF00, CPF01, CPF06, Uv1, oFA00, oFb00 or oFC00
fault occurs, no fault trace is performed.
All Modes
Sets the number of samplings of the data to be registered after a fault is
detected in high-speed tracing.
Note: 1. Available only when a fault has been detected and the drive
automatically stopped.
2. When a CPF00, CPF01, CPF06, Uv1, oFA00, oFb00 or oFC00
fault occurs, no fault trace is performed.
All Modes
Sets the number of samplings of the data to be registered after a fault is
detected in low-speed tracing.
Note: 1. Available only when a fault has been detected and the drive
automatically stopped.
2. When a CPF00, CPF01, CPF06, Uv1, oFA00, oFb00 or oFC00
fault occurs, no fault trace is performed.
All Modes
Selects the stop conditions for tracing.
0: Fault always detected
1: Fault detected during run
Note: When a CPF00, CPF01, CPF06, Uv1, oFA00, oFb00 or oFC00 fault
occurs, no fault trace is performed.
Description
1.3 Parameter Table
Setting
common_
Default: 0
Min: b1-01
Max: o4-
common_
Default: 0
Min: 0
Max: 1
common_
Default:
<10>
Min: 0
Max: 899
common_
Default: 0.000 s
Min: 0.000 s
Max: 10.000 s
common_
Default: 0.05 s
Min: 0.01 s
Max: 60.00 s
common_
Default: 200
Min: 0
Max: 250
common_
Default: 50
Min: 0
Max: 250
common_
Default: 0
Min: 0
Max: 1
page
93
93
94
94
94
94
94