YASKAWA FSDrive-MV1000 Parameter Manual page 76

Super energy-saving medium-voltage ac drive, 2.4 kv class, 3 kv class, 4.16 kv class, 6 kv class, 11 kv class
Hide thumbs Also See for FSDrive-MV1000:
Table of Contents

Advertisement

1.3 Parameter Table
No.
Name
(Addr.)
U4-21
Run Command
(7DDH)
Source Selection
MEMOBUS/
U4-22
Modbus
(7DEH)
Communications
Reference
Communication
U4-23
Option Card
(7DFH)
Reference
U4-33
Transformer
(1040H)
Temperature
U4-90
Calendar Year
(30D0H)
U4-91
Calendar Month
(30D1H)
and Day
U4-92
Calendar Hour
(30D2H)
and Minute
U4-93
Calendar Minute
(30D3H)
and Second
U5-01
PID Feedback
(57H)
U5-02
PID Input
(63H)
U5-03
PID Output
(64H)
U5-04
PID Setpoint
(65H)
Value
U5-05
Differential PID
(7D2H)
Feedback
76
All Modes
Displays the source for the Run command as XY-nn.
X: Indicates which Run source is used:
1 = Reference 1 (b1-02)
2 = Reference 2 (b1-16)
Y: Input power supply data
0 = Digital operator
1 = External terminals
3 = MEMOBUS/Modbus communications
4 = Communication option card
nn: Run command limit status data
00: No limit status.
01: Run command was left on when stopped in the PRG mode
02: Run command was left on when switching from LOCAL to REMOTE
operation
03: Waiting for soft charge bypass contactor after power up (Uv or Uv1
flashes after 10 s)
04: Waiting for "Run command prohibited" time period to end
05: Fast Stop (contact input, digital operator)
06: b1-17 (Run command given at power-up)
07: During baseblock while coast to stop with timer
08: Frequency reference is below minimal reference during baseblock
09: Waiting for Enter command
10: Run command on during COPY operation
All Modes
Displays the drive control data set by MEMOBUS/Modbus
communications register no. 0001H as a four-digit hexadecimal number.
All Modes
Displays drive control data set by an option card as a four-digit
hexadecimal number.
All Modes
Displays the detected transformer temperature value.
All Modes
Displays the calendar year.
All Modes
Displays the calendar month and day.
All Modes
Displays the calendar hour and minute.
All Modes
Displays the calendar minute and second.
All Modes
Displays the PID feedback value.
All Modes
Displays the amount of PID input (deviation between PID setpoint and
feedback).
All Modes
Displays PID control output.
All Modes
Displays the PID setpoint.
All Modes
Displays the 2nd PID feedback value if differential feedback is used (H3-
= 16).
Description
U5: PID Monitors
YASKAWA ELECTRIC EZZ010930 FSDrive-MV1000 Parameter Guide
Analog Output
Level
common_
No signal output
available
common_
No signal output
available
common_
No signal output
available
common_
10 V: 200.0°C
No signal output
common_
available
common_
No signal output
available
common_
No signal output
available
common_
No signal output
available
10 V: Max
common_
frequency
common_
10 V: Max
frequency
10 V: Max
common_
frequency
10 V: Max
common_
frequency
common_
10 V: Max
frequency
Unit
Page
0.1°C
1
01.01
01.01
01.01
0.01%
0.01%
0.01%
0.01%
0.01%