1.3 Parameter Table
No.
Name
(Addr.)
E3-04
Motor 2 Maximum
(31AH)
Output Frequency
E3-05
Motor 2 Maximum
(31BH)
Voltage
E3-06
Motor 2 Base
(31CH)
Frequency
E3-07
Motor 2 Mid
(31DH)
Output Frequency
Motor 2 Mid
E3-08
Output Frequency
(31EH)
Voltage
E3-09
Motor 2 Minimum
(31FH)
Output Frequency
E3-10
Motor 2 Minimum
(320H)
Output Voltage
E3-11
Motor 2 Mid
(345H)
Output Frequency 2
E3-12
Motor 2 Mid
(346H)
Output Frequency
Voltage 2
<24>
E3-13
Motor 2 Base
(347H)
Voltage
E4-01
Motor 2 Rated
(321H)
Current
E4-02
Motor 2 Rated Slip
(322H)
E4-03
Motor 2 Rated No-
(323H)
Load Current
E4-04
Motor 2 Motor
(324H)
Poles
E4-05
Motor 2 Line-to-
(325H)
Line Resistance
E4-06
Motor 2 Leakage
(326H)
Inductance
Motor 2 Motor
E4-07
Iron-Core
(343H)
Saturation
Coefficient 1
38
All Modes
To set linear V/f characteristics, set the same values for E3-07 and E3-09.
In this case, the setting for E3-08 will be disregarded. Ensure that the four
frequencies are set according to these rules or an oPE10 fault will occur:
E3-04 ≥ E3-06 > E3-07 ≥ E3-09
Output Voltage (V)
E3-05
E3-12
E3-13
E3-08
E3-10
E3-09
Note: E3-07 and E3-08 are only available in the following control modes:
V/f Control, Open Loop Vector.
E4: Motor 2 Parameters
All Modes
Sets the full load current for motor 2. Automatically set during
Auto-Tuning.
All Modes
Sets the rated slip for motor 2. Automatically set during Auto-Tuning.
All Modes
Sets the no-load current for motor 2. Automatically set during
Auto-Tuning.
All Modes
Sets the number of poles of motor 2. Automatically set during
Auto-Tuning.
All Modes
Sets the phase-to-phase resistance for motor 2. Automatically set during
Auto-Tuning.
All Modes
Sets the voltage drop for motor 2 due to motor leakage inductance as a
percentage of rated voltage.
V/f
OLV
Set to the motor iron saturation coefficient at 50% of magnetic flux for
motor 2. Automatically set during Auto-Tuning.
Description
E3-07 E3-06 E3-11 E3-04
Frequency (Hz)
CLV
YASKAWA ELECTRIC EZZ010930 FSDrive-MV1000 Parameter Guide
Setting
Default:
<25>
Min: 40.0 Hz
Max: 120.0 Hz
Default:
<25>
Min: 0.0 V
Max: 13000 V
Default:
<25>
Min: 0 Hz
common_
Max: 120 Hz
Default:
<25>
Min: 0.0 Hz
Max: 120.0 Hz
Default:
<25>
Min: 0 V
Max: 13000 V
Default:
<25>
Min: 0.0 Hz
Max: 120.0 Hz
Default:
<25>
Min: 0 V
Max: 13000 V
Default: 0.0
<24>
Min: 0.0 Hz
Max: 120.0 Hz
Default: 0 V
<67>
Max: 0 V
Max: 13000 V
Default: 0 V
<67>
Max: 0 V
Max: 13000 V
Default:
<6>
common_
Min: 10% of drive
rated current
Max: 200% of
drive rated current
Default:
<6>
common_
Min: 0.00 Hz
Max: 20.00 Hz
Default:
common_
<6>
Min: 0 A
Max: E4-01
common_
Default: 4
Min: 2
Max: 48
Default:
common_
<6>
Min: 0.000 Ω
Max: 65.000 Ω
Default:
common_
<6>
Min: 0.0%
Max: 40.0%
Default: 0.50
common
Min: 0.00
Max: 0.50
page
155
155
155
155
155
155
155
155
155
155
156
156
156
156
156
157
157

Advertisement

Table of Contents
loading