4.1 Outline

4.1
Outline
Synchronized Stopping is a function that synchronizes the axes and stops the Servomotors
when an alarm occurs. Specifically, when an alarm occurs on either axis A or axis B, the syn-
chronized stopping axis is synchronized to the active alarm axis, and both Servomotors are
stopped together.
This function can prevent damage to the machine by synchronizing and stopping axis A and
axis B.
Not U ing ynchronized topping
4-2
Mechanical
Axi A
topped by
damage
alarm
U ing ynchronized topping
Axi A topped
現  
Axi B
by alarm
問  
ynchronized
topping prevent
twi ting!
Axi A
Axi B

Hide quick links: