YASKAWA Sigma-7 Series Product Manual page 198

Ac servo drive
Hide thumbs Also See for Sigma-7 Series:
Table of Contents

Advertisement

Parameter
Name
No.
Communications Con-
2
trols 2
MECHATROLINK Communications Error Holding Brake Signal Setting

n.
X
Pn884
*8
M3

n.
X
Reserved parameter (Do not change.)

n.
X
Reserved parameter (Do not change.)

n.X
Reserved parameter (Do not change.)
MECHATROLINK
Receive Error Counter
Pn88A
2
Monitor
(for maintenance, read
only)
Command Data Moni-
tor during Alarm/Warn-
Pn890 to
4
ing
Pn8A6
(for maintenance, read
only)
Response Data Monitor
Pn8A8 to
during Alarm/Warning
4
(for maintenance, read
Pn8BE
only)
Number of Parameter
Pn900
2
Banks
Number of Parameter
Pn901
2
Bank Members
Pn902 to
Parameter Bank Mem-
2
ber Definition
Pn910
Parameter Bank Data
Pn920 to
2
(Not saved in nonvolatile
Pn95F
memory.)
*1.
Refer to the following manual for details.
Σ
Σ
-7-Series
-7W SERVOPACK with MECHATROLINK-III Communications References Product Manual
(Manual No.: SIEP S800001 29)
*2.
Refer to the following manual for details.
Σ-7-Series AC Servo Drive MECHATROLINK-III Communications Standard Servo Profile Command Manual
(Manual No.: SIEP S800001 31)
*3.
Set a percentage of the motor rated torque.
*4.
Normally set this parameter to 0. If you use an External Regenerative Resistor, set the capacity (W) of the Exter-
nal Regenerative Resistor.
*5.
The upper limit is two times the maximum output capacity (W) of the SERVOPACK.
*6.
These parameters are for SERVOPACKs with the dynamic brake option. Refer to the following manual for
details.
Σ-7-Series AC Servo Drive Σ-7S/Σ-7W SERVOPACK with Dynamic Brake Hardware Option Specifications Prod-
uct Manual (Manual No.: SIEP S800001 73)
*7.
The SGLFW2 is the only Yaskawa Linear Servomotor that supports this function.
*8.
Enabled only when Pn61A is set to n.2 or n.3.
*9.
This parameter is valid only when the MECHATROLINK-III standard servo profile is used.
*10.
The parameter setting is enabled after SENS_ON command execution is completed.
*11.
Change the setting when the reference is stopped (i.e., while DEN is set to 1). If you change the setting during
operation, the reference output will be affected.
*12.
The settings are updated only if the reference is stopped (i.e., only if DEN is set to 1).
*13.
Refer to the following manual for details.
Σ-7-Series AC Servo Drive MECHATROLINK-II Communications Command Manual (Manual No.: SIEP S800001
30)
*14.
This parameter is valid only when the MECHATROLINK-II-compatible profile is used.
*15.
The setting of Pn842 is valid while Pn817 is set to 0.
*16.
The setting of Pn844 is valid while Pn818 is set to 0.
*17.
You can check overspeed detection speed with MECHATROLINK-III Common Parameter 05 PnA0A (Maximum
Output Speed).
Setting
Setting
Range
Unit
0000h to
0001h
Maintain the status set by the BRK_ON or BRK_OFF command when a MECHA-
0
TROLINK communications error occurs.
1
Apply the holding brake when a MECHATROLINK communications error occurs.
0 to 65,535
0h to
FFFFFFFFh
0h to
FFFFFFFFh
0 to 16
0 to 15
0000h to
08FFh
0000h to
FFFFh
7.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
Immedi-
0000h
All
ately
0
All
0h
All
0h
All
After
0
All
restart
After
0
All
restart
After
0000h
All
restart
Immedi-
0000h
All
ately
Classi-
Refer-
fication
ence
*2
Setup
Setup
*1
Setup
*1
Setup
*2
Setup
*2
Setup
*2
Setup
*2
Setup
7
7-55