Alarm
Alarm Name
Number
A.050
Combination Error
Unsupported Device
A.051
Alarm
Motor Type Change
A.070
Detected
Linear Encoder Pitch
A.080
Setting Error
Invalid Servo ON
A.0b0
Command Alarm
A.100
Overcurrent Detected
Motor Overcurrent
A.101
Detected
A.300
Regeneration Error
All Axes
A.320
Regenerative Overload
All Axes
A.330
Main Circuit Power Supply
All Axes
Wiring Error
A.400
Overvoltage
All Axes
A.410
Undervoltage
All Axes
Position Deviation
A.50D
between Axes Overflow
All Axes
Alarm
A.510
Overspeed
A.51A
Synchronized Stopping
All Axes
Overspeed Alarm
A.520
Vibration Alarm
A.521
Autotuning Alarm
Maximum Speed Setting
A.550
Error
A.710
Instantaneous Overload
A.720
Continuous Overload
A.730
Dynamic Brake Overload
A.731
A.740
Inrush Current Limiting
All Axes
Resistor Overload
Internal Temperature Error
A.7A1
1 (Control Board Tempera-
All Axes
ture Error)
Alarm Meaning
The capacities of the SERVOPACK and Servomo-
tor do not match.
An unsupported device was connected.
The connected motor is a different type of motor
from the previously connected motor.
The setting of Pn282 (Linear Encoder Scale Pitch)
has not been changed from the default setting.
The SV_ON (Servo ON) command was sent from
the host controller after a utility function that turns
ON the Servomotor was executed.
An overcurrent flowed through the power transis-
tor or the heat sink overheated.
The current to the motor exceeded the allowable
current.
There is an error related to regeneration.
A regenerative overload occurred.
• The AC power supply input setting or DC power
supply input setting is not correct.
• The power supply wiring is not correct.
The main circuit DC voltage is too high.
The main circuit DC voltage is too low.
The position deviation between axes A and B
during the servo ON state exceeded the setting
value of Pn66A (Position Deviation Between Axes
Overflow Alarm Level).
The motor exceeded the maximum speed.
The feedback speed of the axis undergoing syn-
chronized stopping has more than doubled from
the starting speed of synchronized stopping.
Abnormal oscillation was detected in the motor
speed.
Vibration was detected during autotuning for the
tuning-less function.
The setting of Pn385 (Maximum Motor Speed) is
greater than the maximum motor speed.
The Servomotor was operating for several sec-
onds to several tens of seconds under a torque
that largely exceeded the rating.
The Servomotor was operating continuously
under a torque that exceeded the rating.
When the dynamic brake was applied, the rota-
tional or linear kinetic energy exceeded the
capacity of the dynamic brake resistor.
The main circuit power supply was frequently
turned ON and OFF.
The surrounding temperature of the control PCB
is abnormal.
6.1 Alarm Displays
6.1.1 List of Alarms
Continued from previous page.
Servo-
Alarm
motor
Reset
Stop-
Possi-
ping
ble?
Method
Gr.1
Yes
Gr.1
No
Gr.1
No
Gr.1
No
Gr.1
Yes
Gr.1
No
Gr.1
No
Gr.1
Yes
Gr.2
Yes
Gr.1
Yes
Gr.1
Yes
Gr.2
Yes
Gr.1
Yes
Gr.1
Yes
Gr.1
Yes
Gr.1
Yes
Gr.1
Yes
Gr.1
Yes
Gr.2
Yes
Gr.1
Yes
Gr.1
Yes
Gr.1
Yes
Gr.2
Yes
Continued on next page.