2.1 Ratings
2.1
Ratings
This section gives the ratings of SERVOPACKs.
Three-Phase, 200 VAC
Maximum Applicable Motor Capacity per Axis [kW]
Continuous Output Current per Axis [Arms]
Instantaneous Maximum Output Current per Axis
[Arms]
Main Circuit
Control
Power Supply Capacity [kVA]*
Power Loss*
Regenerative
Resistor
Overvoltage Category
*
This is the net value at the rated load.
2-2
Model SGD7W-
Power Supply
Input Current [Arms]*
Power Supply
Input Current [Arms]*
Main Circuit Power Loss [W]
Control Circuit Power Loss [W]
Built-in Regenerative Resistor
Power Loss [W]
Total Power Loss [W]
Resistance
Built-In
[Ω]
Regenerative
Capacity
Resistor
[W]
Minimum Allowable External
Resistance [Ω]
1R6A
2R8A
0.2
0.4
1.6
2.8
5.9
9.3
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
2.5
4.7
200 VAC to 240 VAC, -15% to +10%, 50 Hz/60 Hz
0.25
0.25
1.0
1.9
24.0
43.3
17
17
8
8
49.0
68.3
40
40
40
40
40
40
III
5R5A
7R6A
0.75
1.0
5.5
7.6
16.9
17.0
7.8
11
0.25
0.25
3.2
4.5
78.9
94.2
17
17
16
16
111.9
127.2
12
12
60
60
12
12