7.2 List of Servo Parameters
Parameter
No.
Pn511
7-26
Name
Input Signal Selections
2
5
/DEC (Origin Return Deceleration Switch Input) Signal Allocation
Axis A: Active when CN1-3 input signal is ON (closed).
0
Axis B: Active when CN1-9 input signal is ON (closed).
Axis A: Active when CN1-4 input signal is ON (closed).
1
Axis B: Active when CN1-10 input signal is ON (closed).
Axis A: Active when CN1-5 input signal is ON (closed).
2
Axis B: Active when CN1-11 input signal is ON (closed).
Axis A: Active when CN1-6 input signal is ON (closed).
3
Axis B: Active when CN1-12 input signal is ON (closed).
Axis A: Active when CN1-7 input signal is ON (closed).
4
Axis B: Active when CN1-13 input signal is ON (closed).
Axis A: Active when CN1-8 input signal is ON (closed).
5
Axis B: Active when CN1-14 input signal is ON (closed).
6
Reserved setting (Do not use.)

n.
X
7
The signal is always active.
8
The signal is always inactive.
Axis A: Active when CN1-3 input signal is OFF (open).
9
Axis B: Active when CN1-9 input signal is OFF (open).
Axis A: Active when CN1-4 input signal is OFF (open).
A
Axis B: Active when CN1-10 input signal is OFF (open).
Axis A: Active when CN1-5 input signal is OFF (open).
B
Axis B: Active when CN1-11 input signal is OFF (open).
Axis A: Active when CN1-6 input signal is OFF (open).
C
Axis B: Active when CN1-12 input signal is OFF (open).
Axis A: Active when CN1-7 input signal is OFF (open).
D
Axis B: Active when CN1-13 input signal is OFF (open).
Axis A: Active when CN1-8 input signal is OFF (open).
E
Axis B: Active when CN1-14 input signal is OFF (open).
F
Reserved setting (Do not use.)
/EXT1 (External Latch Input 1) Signal Allocation
0 to 2
The signal is always inactive.
Axis A: Active when CN1-6 input signal is ON (closed).
3
Axis B: Active when CN1-12 input signal is ON (closed).
Axis A: Active when CN1-7 input signal is ON (closed).
4
Axis B: Active when CN1-13 input signal is ON (closed).
Axis A: Active when CN1-8 input signal is ON (closed).
5
Axis B: Active when CN1-14 input signal is ON (closed).

n.
X
6 to B
The signal is always inactive.
Axis A: Active when CN1-6 input signal is OFF (open).
C
Axis B: Active when CN1-12 input signal is OFF (open).
Axis A: Active when CN1-7 input signal is OFF (open).
D
Axis B: Active when CN1-13 input signal is OFF (open).
Axis A: Active when CN1-8 input signal is OFF (open).
E
Axis B: Active when CN1-14 input signal is OFF (open).
F
The signal is always inactive.
/EXT2 (External Latch Input 2) Signal Allocation

n.
X
The allocations are the same as the /EXT1 (External Latch Input 1) signal allo-
0 to F
cations.
/EXT3 (External Latch Input 3) Signal Allocation

n.X
The allocations are the same as the /EXT1 (External Latch Input 1) signal allo-
0 to F
cations.
Setting
Setting
Default
Range
Unit
Setting
0000h to
5432h
FFFFh
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Continued on next page.
Refer-
ence
*1