Saving The Position Correction Table To Non-Volatile Memory - YASKAWA Sigma-7 Series Product Manual

Ac servo drive
Hide thumbs Also See for Sigma-7 Series:
Table of Contents

Advertisement

 Example of Setting Pre-Correction Position [1] in the Position Correction Table to
-500,000
The follow examples writes a pre-correction position in the Position Correction Table to volatile
memory.
ADDRESS = 0xF0040004
MODE/DATA_TYPE = 0x13
SIZE = 0x01
DATA = -500000
 Saving the Position Correction Table to Non-Volatile Memory
 How to Save Position Correction Table Data
Save the current values in volatile memory to non-volatile memory. Send the commands in the
following order.
Step
Sets the request code for writing to non-
1
volatile memory.
Executes preparation processing 1 for
2
writing to non-volatile memory.
Executes preparation processing 2 for
3
writing to non-volatile memory.
Executes preparation processing 3 for
4
writing to non-volatile memory.
5
Executes writing to non-volatile memory.
6
Terminates writing to non-volatile memory.
This concludes the procedure to save the Position Correction Table to non-volatile memory.
Description
3.4 Position Correction Table Settings
3.4.4 Setting Method with the MEM_WR Command
Setting Example
ADDRESS = 0x80004000
MODE/DATA_TYPE = 0x12
SIZE = 0x0001
DATA = 0x2025
ADDRESS = 0x800041E0
MODE/DATA_TYPE = 0x12
SIZE = 0x0001
DATA = 0x0000
ADDRESS = 0x800041E4
MODE/DATA_TYPE = 0x13
SIZE = 0x0001
DATA = 0xF0040000
ADDRESS = 0x80004002
MODE/DATA_TYPE = 0x12
SIZE = 0x0001
DATA = 0x0002
ADDRESS = 0x80004002
MODE/DATA_TYPE = 0x12
SIZE = 0x0001
DATA = 0x0001
ADDRESS = 0x80004000
MODE/DATA_TYPE = 0x12
SIZE = 0x0001
DATA = 0x0000
3
3-21