Parameter
Name
No.
Input Signal Selections
2
1
I/O Signal Allocation Mode
n.
X
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
P-OT (Forward Drive Prohibit) Signal Allocation
Pn50A
n.X
Setting
Setting
Range
Unit
0000h to
–
FFF2h
0
Reserved setting (Do not use.)
Use Σ-7S-compatible I/O signal allocations (Pn50A to Pn517).
1
2
Use multi-axis I/O signal allocations (Pn590 to Pn5BC).
Axis A: Enable forward drive when CN1-3 input signal is ON (closed).
0
Axis B: Enable forward drive when CN1-9 input signal is ON (closed).
Axis A: Enable forward drive when CN1-4 input signal is ON (closed).
1
Axis B: Enable forward drive when CN1-10 input signal is ON
(closed).
Axis A: Enable forward drive when CN1-5 input signal is ON (closed).
2
Axis B: Enable forward drive when CN1-11 input signal is ON
(closed).
Axis A: Enable forward drive when CN1-6 input signal is ON (closed).
3
Axis B: Enable forward drive when CN1-12 input signal is ON
(closed).
Axis A: Enable forward drive when CN1-7 input signal is ON (closed).
4
Axis B: Enable forward drive when CN1-13 input signal is ON
(closed).
Axis A: Enable forward drive when CN1-8 input signal is ON (closed).
5
Axis B: Enable forward drive when CN1-14 input signal is ON
(closed).
6
Reserved setting (Do not use.)
7
Set the signal to always prohibit forward drive.
8
Set the signal to always enable forward drive.
Axis A: Enable forward drive when CN1-3 input signal is OFF (open).
9
Axis B: Enable forward drive when CN1-9 input signal is OFF (open).
Axis A: Enable forward drive when CN1-4 input signal is OFF (open).
A
Axis B: Enable forward drive when CN1-10 input signal is OFF (open).
Axis A: Enable forward drive when CN1-5 input signal is OFF (open).
B
Axis B: Enable forward drive when CN1-11 input signal is OFF (open).
Axis A: Enable forward drive when CN1-6 input signal is OFF (open).
C
Axis B: Enable forward drive when CN1-12 input signal is OFF (open).
Axis A: Enable forward drive when CN1-7 input signal is OFF (open).
D
Axis B: Enable forward drive when CN1-13 input signal is OFF (open).
Axis A: Enable forward drive when CN1-8 input signal is OFF (open).
E
Axis B: Enable forward drive when CN1-14 input signal is OFF (open).
F
Reserved setting (Do not use.)
7.2 List of Servo Parameters
Continued from previous page.
Default
Applicable
When
Setting
Motors
Enabled
After
0881h
All
restart
Continued on next page.
Classi-
Refer-
fication
ence
Setup
–
Reference
*1
Reference
*1
7