7.2 List of Servo Parameters
Parameter
No.
Pn50E
Pn50F
7-24
Name
Output Signal Selec-
2
tions 1
/COIN (Positioning Completion Output) Signal Allocation
0
Disabled (the above signal output is not used).
Axis A: Output the signal from the CN1-23 or CN1-24 output ter-
minal.
1
Axis B: Output the signal from the CN1-25 or CN1-26 output ter-

n.
X
minal.
Axis A: Output the signal from the CN1-27 or CN1-28 output ter-
minal.
2
Axis B: Output the signal from the CN1-29 or CN1-30 output ter-
minal.
3 to 6
Reserved settings (Do not use.)
/V-CMP (Speed Coincidence Detection Output) Signal Allocation

n.
X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
/TGON (Rotation Detection Output) Signal Allocation

n.
X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
/S-RDY (Servo Ready) Signal Allocation

n.X
The allocations are the same as the /COIN (Positioning Comple-
0 to 6
tion) signal allocations.
Output Signal Selec-
2
tions 2
/CLT (Torque Limit Detection Output) Signal Allocation
0
Disabled (the above signal output is not used).
Axis A: Output the signal from the CN1-23 or CN1-24 output ter-
minal.
1
Axis B: Output the signal from the CN1-25 or CN1-26 output ter-

n.
X
minal.
Axis A: Output the signal from the CN1-27 or CN1-28 output ter-
minal.
2
Axis B: Output the signal from the CN1-29 or CN1-30 output ter-
minal.
3 to 6
Reserved settings (Do not use.)
/VLT (Speed Limit Detection) Signal Allocation

n.
X
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
/BK (Brake Output) Signal Allocation

n.
X
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
/WARN (Warning Output) Signal Allocation

n.X
The allocations are the same as the /CLT (Torque Limit Detection
0 to 6
Output) signal allocations.
Setting
Setting
Default
Range
Unit
Setting
0000h to
0000h
6666h
0000h to
0100h
6666h
Continued from previous page.
Applicable
When
Classi-
Motors
Enabled
fication
After
All
Setup
restart
Reference
Reference
Reference
Reference
After
All
Setup
restart
Reference
Reference
Reference
Reference
Continued on next page.
Refer-
ence
*1
*1
*1
*1
*1
*1
*1
*1