4. RESPONSE Block

A group of keys used mainly for setting up response measurements on the E5070/E5071A.
Key
Key
Key
Key
Key
Key
Key
Key
Chapter 2
Front Panel: Names and Functions of Parts
Changes between normal and maximum display of the
active channel window. In normal display, all the defined
channel windows (both active and non-active) are
displayed in split views on the screen. In maximum display,
only the active channel window is displayed over the entire
area, with non-active windows not displayed. To maximize
the active channel, double-click the channel window frame.
Measurements are also carried out on the non-active
channels that are not displayed.
Changes between normal and maximum display of the
active trace. In normal display, all traces defined on the
channel (both active and non-active) are displayed on the
screen. In maximum display, only the active trace is
displayed over the entire area, with non-active traces not
displayed. To maximize the active trace, double-click the
area inside the channel window (excluding the frame).
Measurements are also carried out on the non-active traces
not displayed.
Displays the Measurement softkey menu on the right side
of the screen. Manipulating the Measurement menu enables
you to specify the measurement parameters (types of
S-parameters) for each trace.
Displays the Format softkey menu on the right side of the
screen. Manipulating the Format menu enables you to
specify the data format (data transformation and graph
formats) for each trace.
Displays the Scale softkey menu on the right side of the
screen. Manipulating the Scale menu enables you to
specify the scale for displaying a trace (magnitude per
division, value of the reference line, etc.) for each trace.
You can also specify the electrical delay and phase offset
for each trace.
Displays the Display softkey menu on the right side of the
screen. Manipulating the Display menu enables you to
specify the number of channels and channel window array,
the number and arrangement of traces, the setup for data
math, etc.
Displays the Average softkey menu on the right side of the
screen. Manipulating the Average menu enables you to
define the averaging, smoothing, and IF bandwidth.
Displays the Calibration softkey menu on the right side of
the screen. Manipulating the Calibration menu enables you
to turn the calibration and error correction on/off and
change definitions for calibration kits.