Connection of one cable technology (OCT) via HIPERFACE DSL®
Preconditions
• The one cable technology (OCT) is possible with MCS and m850 servo motors from Lenze.
• The motor must be provided with a HIPERFACE DSL® encoder.
• The Lenze hybrid cable EYP0080AxxxxM11A00 or EYP0080AxxxxM11A00 must be used as a connection
cable.
• Make sure no motor encoder module is plugged into slot A.
• One Cable Technology can only be used with the "Basic Safety STO" version.
Lenze hybrid cables EYP0080AxxxxM1xA00 ensure only basic insulation to power electronics.
Connection diagram
gnye
Fig. 18: Connection diagram HIPERFACE DSL® (OCT)
bk
bk
bk
wh
1
2
3
+DSL
EYP0080AxxxxM1xA00
M 3~
Connection of one cable technology (OCT) via HIPERFACE DSL®
bl
-DSL
DC 24 V SELV/PELV
(+19.2 V ... +28.8 V)
Electrical installation
bk
bk
5
6
+
-
159