Set the Channel Power Span
[:SENSe]:CHPower:FREQuency:SPAN <freq>
[:SENSe]:CHPower:FREQuency:SPAN?
Press Chan Pwr Span to set the analyzer span for the channel
power measurement.
*RST:
3.0 GHz
Range:
Current integration bandwidth to 10 times the integration
bandwidth or span of your analyzer.
Example:
CHP:FREQ:SPAN 2 MHz
Key access:
Meas
[:SENSe]:CORRection Subsection
External Amplifier Correction
[:SENSe]:CORRection:OFFSet[:MAGNitude] <rel_ampl>
[:SENSe]:CORRection:OFFSet[:MAGNitude]?
A single value of amplitude correction can be applied to the
displayed trace data to compensate for signal losses/gains that are
due to other devices in the measurement setup, rather than the
unit under test.
*RST:
0 dB
Range:
–81.9 to 81.9
Key access:
Amplitud
Impendance Conversion
[:SENSe]:CORRection:IMPedance[:INPut][:MAGNitude]
50|75
[:SENSe]:CORRection:OFFSet[:MAGNitude]?
Toggles the computational input impedance between 75 and 50
ohm. And this is only software function in which sets the input
impedance for unit conversions. The actual impedance is set by
> Channel Power > Chan Pwr Span
> More > Ext Amp Gain
Command Reference
SENSe Subsystem
129