Command Reference
SYSTem Subsystem
Key access:
Key access:
Key access:
Key access:
160
Display System Configuration
:SYSTem:CONFigure[:SYSTem]:STATe OFF|ON|0|1
:SYSTem:CONFigure[:SYSTem]:STATe?
Shows the current system configuration of the instrument on the
display.
*RST:
Off
> More > Show System
Preset/
System
Set Date
:SYSTem:DATE <year>,<month>,<day>
:SYSTem:DATE?
Sets the date of the real-time clock of the instrument. Year is a
4-digit integer. Month is an integer 1 to 12. Day is an integer 1 to
31 (depending on the month)
> More > Time/Date > Set Date
Preset/
System
Error Information Query
:SYSTem:ERRor[:NEXT]?
This command queries the earliest entry to the error queue and
then deletes that entry. *CLS clears the entire error queue.
> More > Show Errors
Preset/
System
Query Instrument Options
:SYSTem:OPTions?
Returns a list of the options that are installed.
It is a comma separated list such as: "TG3,PA3"
> More > Show System
Preset/
System