Keysight N9320B Programmer's Manual page 132

Spectrum analyzer
Hide thumbs Also See for N9320B:
Table of Contents

Advertisement

Command Reference
SENSe Subsystem
Key access:
Key access:
126
Set:LIST[:FREQuency]
Set:LIST:STATe
Table 1 shows the default array.
Example:
Sending fewer than 6 items to these commands will leave the
values of the unspecified offsets unchanged. If you don't send
settings for all 6 offsets, it will set all the offsets that you specified,
then it will set any remaining offsets to the same setting as the last
offset that you sent.
ACP:OFFS:LIST:BAND 50,50,50,50,50,50
> ACP > Chan Integ BW
Meas
Set the Offset Freq
[:SENSe]:ACPower:OFFSet:LIST[:FREQuency]
<freq>,<freq>,<freq>,<freq>,<freq>,<freq>
[:SENSe]:ACPower:OFFSet:LIST[:FREQuency]?
[:SENSe]:ACPower:OFFSet:LIST:STATe
OFF|ON|0|1,OFF|ON|0|1,OFF|ON|0|1,OFF|ON|0|1,OFF|ON|0|
1,OFF|ON|0|1
[:SENSe]:ACPower:OFFSet:LIST:STATe?
Enables you to set the frequency difference from the center of the
main channel to the center of the offset for a maximum of 6 offsets
(labeled A-F). It also allows you to turn on/off the offsets that you
want to measure.
*RST:
The default value is defined by the selected Offset label. This
command, along with commands
[:SENSe]:ACPower:OFFSet:LIST[:FREQuency]
[:SENSe]:ACPower:OFFSet:LIST:STATe
array of values. Please refer to the Table 1.
Example:
ACP:OFFS:LIST 50 Hz,75 Hz,100 Hz,125 Hz,150 Hz,175 Hz
ACP:OFFS:LIST:STAT ON,ON,ON,OFF,OFF,OFF
For example, after the above command is sent, sending the
command with only four paramenters
ON,ON,ON,OFF)
same as the previous setting (OFF).
> ACP > Offset/Limits > Offset Freq
Meas
and
[:SENSe]:ACPower:OFF-
are used to set an entire array of values. The
will result in the fifth and sixth offset remaining the
and
are used to set an entire
(ACP:OFFS:LIST:STAT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents