*RST:
Off
Example:
ACP:LIM 1
> ACP > More > Limits
Key access:
Meas
Set the Measurement Method
[:SENSe]:ACPower:METHod IBW|RBW
[:SENSe]:ACPower:METHod?
Enables you to set the measurement method. The resolution
bandwidth method is most useful for measuring the signals the
bandwidths of which is approximate to the RBW of the Analyzer;
the integration bandwidth method is preferred for other signals.
*RST:
IBW
Example:
ACP:METH:RBW
> ACP > More > Method
Key access:
Meas
Set the Ref BW
[:SENSe]:ACPower:OFFSet:LIST:BANDwidth|BWIDth[:INTe-
gration] <freq>,<freq>,<freq>,<freq>,<freq>,<freq>
[:SENSe]:ACPower:OFFSet:LIST:BANDwidth|BWIDth[:INTegr
ation]?
Sets the reference bandwidth (integration bandwidth) for each
offset.
*RST:
The default value is defined by the selected Offset label.
Table 1
Offset
A
B
C
D
E
F
This command along with commands
Offset parameters in ACP measurement
State
Frequency
ON
3 MHz
OFF
0 Hz
OFF
0 Hz
OFF
0 Hz
OFF
0 Hz
OFF
0 Hz
Command Reference
SENSe Subsystem
Integ. BW
2 MHz
2 MHz
2 MHz
2 MHz
2 MHz
2 MHz
[:SENSe]:ACPower:OFF-