Set the Max Mixer Lvl
[:SENSe]:TOI:FREQuency:MIXer:RANGe[:UPPer] <number>
[:SENSe]:TOI:FREQuency:MIXer:RANGe[:UPPer]?
[:SENSe]:TOI:FREQuency:MIXer:RANGe:AUTO OFF|ON|0|1
[:SENSe]:TOI:FREQuency:MIXer:RANGe:AUTO?
Enables you to set the relationship between the highest signal that
can be displayed (the reference level) and the input attenuation.
The relationship applies whenever the Attenuation is set to Auto.
The relationship is that the attenuation is given by reference level
minus the max mixer level. For example, as the reference level
changes, the input attenuator changes to ensure that a signal at
the reference level does not exceed the Max Mixer Lvl setting.
When the TOI measurement is on, this key controls the maximum
mixer level, independent of the previous setting of Max Mixer Lvl
located under Amplitude. When the TOI measurement is Off, the
previous
maximum Max Mixer Lvl is restored. Setting Max Mixer Lvl to Auto
sets the maximum mixer level to –30 dBm.
*RST:
–30 dBm
Range:
–100 dBm to 0 dBm
Example:
OBW:TOI COUN 20
> More > TOI > Max Mixer Lvl
Key access:
Meas
Set TOI Span
[:SENSe]:TOI:FREQuency:SPAN <freq>
[:SENSe]:TOI:FREQuency:SPAN?
Specify the frequency span in which intermodulation products are
measured. If you modify the value of Span in the base instrument
Span menu, the value in the Meas menu will be updated to reflect
the new value and the measurement will restart if it is running.
*RST:
15 MHz
Example:
TOI:FREQ:SPAN 20 MHz
> More > TOI > TOI Span
Key access:
Meas