Keysight N9320B Programmer's Manual page 102

Spectrum analyzer
Hide thumbs Also See for N9320B:
Table of Contents

Advertisement

Command Reference
DANalyse Subsystem
Key access:
Key access:
Key access:
Key access:
96
Reference Filter
DANalyse:ASK|FSK:RADio:STANdard:FILTer:REFerence
NONE|RNYQuist|NYQuist|GAUSsian
DANalyse:ASK|FSK:RADio:STANdard:FILTer:REFerence?
Specifies the reference filter type for the ASK/FSK signals.
> ASK/FSK Modulation Analysis > Filter Setup > Ref filter
MODE
Filter Symbols
DANalyse:ASK|FSK:RADio:STANdard:FILTer:SYMBol
<integer>
DANalyse:ASK|FSK:RADio:STANdard:FILTer:SYMBol?
Sets the symbol numbers for the selected filter.
> ASK/FSK Modulation Analysis > Filter Setup > FilterSymbols
MODE
Alpha
DANalyse:ASK|FSK:RADio:STANdard:ALPHa <real>
DANalyse:ASK|FSK:RADio:STANdard:ALPHa?
Sets the root-off factor a for Root Nyquist and Nyquist filter or BbT
for Gaussian filter.
> ASK/FSK Modulation Analysis > Filter Setup > Alpha/BbT
MODE
Measrue Length
DANalyse:ASK|FSK:LENGth <integer>
DANalyse:ASK|FSK:LENGth?
Sets the number of symbols that are used in calculating the
Measurement.
> ASK/FSK Modulation Analysis > More > Meas Length
MODE