Sweep Time
[:SENSe]:SWEep:TIME <time>
[:SENSe]:SWEep:TIME?
Specifies the time in which the instrument sweeps the display.
*RST:
100.2 ms
Remarks:
A span value of 0 Hz causes the analyzer to enter zero span mode.
In zero span the X-axis represents time rather than frequency.
> Sweep Time Auto Man
Sweep/
Trig
Automatic Sweep Time
[:SENSe]:SWEep:TIME:AUTO OFF|ON|0|1
[:SENSe]:SWEep:TIME:AUTO?
Automatically selects the fastest sweep time for the current
settings.
*RST:
On
> Sweep Time Auto Man
Sweep/
Trig
Sweep Type
[:SENSe]:SWEep:TYPE FFT|SWEep
[:SENSe]:SWEep:TYPE?
Set the sweep type to FFT mode or X mode. When the sweep time
is set to AUTO mode, the sweep type is FFT to decrease the sweep
time. In zero span, this command is invalid.
*RST:
On
> Sweep Time Auto Man