Command Reference
SENSe Subsystem
Key access:
Key access:
124
Set ACP Reference Auto
[:SENSe]:ACPower:CARRier:AUTO[:STATe] OFF|ON|0|1
[:SENSe]:ACPower:CARRier:AUTO[:STATe]?
Enables you to set the adjacent channel power reference to
automatic or manual. When set to automatic, the carrier power
result reflects the measured value in the carrier. When set to
manual, the last measured value is captured and held, or may be
entered by the user. Relative values are displayed, referenced to
the value measured in the main channel.
*RST:
Auto ON
Example:
ACP:CARR:AUTO:OFF
> ACP > More > Total Pwr Ref/PSD Ref
Meas
Set ACP Reference Manual
[:SENSe]:ACPower:CARRier[:POWer] <ampl>
[:SENSe]:ACPower:CARRier[:POWer]?
Set the adjacent channel reference when Total Pwr Ref/PSD Ref is
set to Manual, the last measured value is captured and held, or
may be entered by the user. Relative values are displayed,
referenced to the value measured in the main channel.
Example:
ACP:CARR:-40
> ACP > More > Total Pwr Ref/PSD Ref
Meas
Set ACP to Total Pwr Ref
[:SENSe]:ACPower:LIMit[:STATe] OFF|ON|0|1
[:SENSe]:ACPower:LIMit[:STATe]?
When Limit is set to On, each offset is compared to its upper and
lower offset limit. In those cases where the power exceeds the limit,
the pass/fail indicator area show "FAIL" in red to indicate a failure;
if there are none, it shows "PASS" in green. Any offsets that are in
the off state are not measured and their results will not be
displayed on screen.