Keysight N432A manuals available for free PDF download: Programming Manual, Service Manual, Installation Manual
Keysight N432A Programming Manual (511 pages)
Thermistor Power Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 5.46 MB
Table of Contents
General Warranty
3
Restricted Rights Legend
3
Equipment Operation
4
Warnings and Cautions
4
Personal Safety Considerations
4
General Safety Considerations
5
User Environment
5
Table of Contents
7
1 N432A Remote Operation
46
Introduction
46
Introduction to the SCPI Language
47
Mnemonic Forms
47
Using a Colon (:)
47
Using a Semicolon (;)
48
Using a Comma (,)
48
Using Whitespace
48
Using "?" Commands
48
Using "*" Commands
49
Syntax Conventions
49
Syntax Diagram Conventions
49
SCPI Data Types
50
Input Message Terminators
56
Configuring the Remote Interface
57
Interface Selection
57
GPIB Address
57
LAN Configuration
58
USB Configuration
59
Zeroing
60
Making Measurements
61
Using Measure
61
Using the Configure Command
65
Using the Lower-Level Commands
73
Setting the Bridge Resistance
74
Setting the Measurement Frequency
74
Setting Offsets
75
Channel Offsets
75
Display Offsets
75
Using Frequency-Dependent Offset Tables
77
Editing Frequency-Dependent Offset Tables
78
Selecting Frequency-Dependent Offset Tables
80
Enabling a Frequency-Dependent Offset Table
80
Making the Measurement
81
Setting Measurement Limits
82
Checking for Limit Failures
83
Using the Calibration/Correction Factors
85
Setting Frequency-Specific Calibration Factors
85
Using Sensor Calibration Tables
85
Editing Sensor Calibration Tables
86
Selecting Sensor Calibration Tables
89
Enabling Sensor Calibration Tables
89
Making the Measurement
90
Optimizing the N432A Performance
91
Trigger Mode
91
Output Format
92
Units
92
Measurement Commands
93
How Measurements Are Calculated
94
Status Reporting
95
General Status Register Model
95
How to Use Registers
99
Condition Polling Method
99
SRQ Method
100
Using the Operation Complete Commands
113
Saving and Recalling N432A Configurations
115
How to Save and Recall a Configuration
115
Using Device Clear to Halt Measurements
116
Summary of Commands
116
2 IEEE-488 Command Reference
118
SCPI Compliance Information
118
Cls
119
Syntax
119
Example
119
DDT <Arbitrary Block Program Data>|<String Program Data
120
Syntax
120
Parameters
120
Reset Condition
120
Query
121
Error Message
121
ESE <Nrf
122
Syntax
122
Parameter
123
Example
123
Query
123
Query Example
123
Esr
124
Syntax
124
Example
124
Idn
125
Syntax
125
Example
125
Lrn
126
Syntax
126
Example
126
Opc
127
Syntax
127
Example
127
Wai
137
Syntax
137
Example
137
GPIB Universal Commands
138
Dcl
138
Get
138
Gtl
138
Llo
138
Ppc
139
Ppd
139
Ppe
140
Ppu
140
Sdc
141
Spd
141
Spe
141
Measurement Commands
145
Optional Parameters
146
Configure[1]|2|3|4
150
Syntax
150
Example
151
Reset Condition
151
Configure [1]|2|3|4 Commands
152
Configure[1]|2|3|4[:Scalar][:Power:ac] [<Expected_Value>[,<Resolution>[,<Source List>]]]
153
Syntax
153
Parameters
154
Example
154
Configure[1]|2|3|4[:Scalar][:Power:ac]:Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]
155
Syntax
155
Parameters
156
Example
156
Configure[1]|2|3|4[:Scalar][:Power:ac]:Difference [<Expected_Value>[,<Resolution>[,<Source List>]]]
157
Syntax
157
Parameters
158
Example
158
Configure[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]
159
Syntax
159
Parameters
160
Example
160
Configure[1]|2|3|4[:Scalar][:Power:ac]:Ratio [<Expected_Value>[,<Resolution>[,<Source List>]]]
161
Syntax
161
Parameters
162
Example
162
Configure[1]|2|3|4[:Scalar][:Power:ac]:Ratio: Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]
163
Syntax
163
Parameters
164
Example
164
Fetch[1]|2|3|4 Queries
165
Fetch[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]
166
Syntax
166
Parameters
167
Example
167
Error Messages
167
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
168
Syntax
168
Parameters
168
Example
169
Error Messages
169
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Difference
170
Advertisement
Keysight N432A Service Manual (57 pages)
Thermistor Power Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 1.31 MB
Table of Contents
Certification
3
Limitation of Warranty
3
Exclusive Remedies
3
Equipment Operation
4
Warnings and Cautions
4
Personal Safety Considerations
4
Safety Symbols
5
Safety Considerations
6
Environmental Conditions
7
Regulatory Information
8
Safety Compliance
8
EMC Compliance
8
Regulatory Markings
9
IEC 1010-1 Compliance
9
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ EC
10
Product Category
10
Sales and Technical Support
10
Table of Contents
11
1 N432A at a Glance
16
Front Panel Outlook
16
Rear Panel Connections
23
Display Layout
24
Figure 1-1 Dual Numeric Display
24
Figure 1-2 Single Numeric and Analog Display
25
Figure 1-3 Full Screen Numeric Display
26
2 Calibration Procedures
30
Introduction
30
Keysight Technologies Calibration Services
31
Calibration Interval
32
Self-Test
33
Front Panel Selection of Self-Tests
33
Instrument Self-Test
33
Figure 2-1 Self-Test Completed
34
Test Descriptions
35
Figure 2-2 VRF, VCOMP , and
35
Remote Testing
36
3 Performance Tests
37
Introduction
38
Mw Power Reference Level Test
39
Description
39
Required Test Equipment
39
Test Method
39
Figure 3-1 Connecting 8482A to Channel a for 1 Mw Power Reference Level Test
40
Figure 3-2 Connecting 8482A to N432A for 1 Mw Power Reference Level Test
40
Output Standing Wave Ratio (SWR) Test
42
Description
42
Required Test Equipment
42
Figure 3-3 System Calibration Connection Diagram
43
Figure 3-4 Output SWR Test Setup - Open Connection Diagram
43
Test Method
44
Figure 3-5 Output SWR Test Setup - Load Connection Diagram
44
4 Service and Maintenance
50
Introduction
50
Service-Related Features
51
Cleaning
52
Checking the Power Line Fuses
53
Figure 4-1 Checking the Fuses
53
5 Specifications and Characteristics
55
Keysight N432A Installation Manual (55 pages)
Thermistor Power Meter
Brand:
Keysight
| Category:
Measuring Instruments
| Size: 3.9 MB
Table of Contents
Certification
3
General Warranty
3
Warranty Service
3
Limitation of Warranty
4
Exclusive Remedies
4
Safety Symbols
5
Safety Considerations
6
Environmental Conditions
8
Ventilation and Cleaning
9
Ventilation Requirements
9
Cleaning
9
Compliance and Markings
10
Electromagnetic Compatibility (EMC)
10
Safety
10
Sound Emission
11
Responsibilities of the Customer
12
Regulatory Markings
13
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96
14
Product Category
14
Sales and Technical Support
14
Table of Contents
15
1 Getting Started
19
Introduction
20
Initial Inspection
20
Documentation Information
21
Overview
22
Conventions Used in this Guide
23
Sensor Compatibility
23
Adjusting the Carrying Handle
24
Front Panel Outlook
25
Rear Panel Connections
30
Turning on the N432A
31
Connecting a Thermistor Sensor
34
Remote Interface Configurations
36
Usb
37
Figure 1-1 Found New Hardware Wizard
37
Lan
39
Figure 1-2 Enabling DHCP
40
Figure 1-3 LAN Network Restart Pop-Up
41
Figure 1-4 LAN Network Manual Setup
43
Gpib
45
Figure 1-5 Changing the GPIB Address
46
Rack Mounting the N432A
47
Rack Mounting Information
47
Rack Mounting a Single N432A (Using the Option 908 Rack Mount Kit)
48
Rack Mounting Two N432As Together (Using the Option 909 Rack Mount Kit)
50
2 Characteristics and Specifications
53
Advertisement
Advertisement
Related Products
Keysight N437 Series
Keysight N4373C
Keysight N4374B
Keysight N4375E
Keysight N4375D
Keysight N4376E
Keysight N4376D
Keysight N4376B
Keysight N4373B
Keysight N4372E
Keysight Categories
Measuring Instruments
Test Equipment
Multimeter
Control Unit
Portable Generator
More Keysight Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL