Keysight N9320B Programmer's Manual page 144

Spectrum analyzer
Hide thumbs Also See for N9320B:
Table of Contents

Advertisement

Command Reference
SENSe Subsystem
Key access:
Key access:
138
Specifies the resolution bandwidth used in measuring the offset
pair. When set to Auto, the RBW from the default tables are used.
When set to Man, the range of settings is the range of available
RBWs, except the maximum is further limited to not exceed (Stop
Freq - Start Freq).
*RST:
Dependent upon Offset label selected.
Example:
SEM:OFFS:LIST:BAND 40 kHz or SEM:OFFS:LIST:BWID 40 kHz
> More > Spectrum Emission Mask > Ref Channel > Res BW
Meas
Set the Start Freq
[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STARt
<freq>,...[<freq>] (up to five values)
[:SENSe]:SEMask:OFFSet:LIST:FREQuency:STARt?
[:SENSe]:SEMask:OFFSet:LIST:STATe
OFF|ON|0|1,...OFF|ON|0|1 (up to five values)
[:SENSe]:SEMask:OFFSet:LIST:STATe?
Specifies the inner limit (frequency closest to the carrier) for both
segments of the specified offset pair. When Start Freq (Off) is
selected, the offset pair is not measured.
Offsets that are turned off, for the currently selected offset will
return a -999.0 when queried.
*RST:
Dependent upon Offset selected, please refer to the User's Guide
for more details.
Range:
0 Hz to the Stop Freq (for that offset) minus 10 Hz
Example:
SEM:OFFS:LIST:FREQ:STAR 2 MHz
SEM:OFFS:LIST:STAT 1
> More > Spectrum Emission Mask > Offset/Limits > Start Freq
Meas

Hide quick links:

Advertisement

Table of Contents
loading