Fba Settings - ABB ACS850 Firmware Manual

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

No.
Name/Value
50.05
Fba ref2 modesel
Raw data
Torque
Speed
50.06
Fba act1 tr src
Pointer
50.07
Fba act2 tr src
Pointer
50.08
Fba sw b12 src
Const
Pointer
50.09
Fba sw b13 src
Const
Pointer
50.10
Fba sw b14 src
Const
Pointer
50.11
Fba sw b15 src
Const
Pointer
51

51 FBA settings

51.01
FBA type
51.02
FBA par2
...
...
51.26
FBA par26
Description
Selects the fieldbus reference FBA REF2 scaling.
See parameter
50.04 Fba ref1
See parameter
50.04 Fba ref1
See parameter
50.04 Fba ref1
See parameter
50.04 Fba ref1
Selects the source for fieldbus actual value 1 when parameter
50.04 Fba ref1 modesel / 50.05 Fba ref2 modesel
Raw
data.
Value pointer setting (see
63).
Selects the source for fieldbus actual value 2 when parameter
50.04 Fba ref1 modesel / 50.05 Fba ref2 modesel
Raw
data.
Value pointer setting (see
63).
Selects the source for freely programmable fieldbus status
word bit 28
(02.24 FBA main sw
Bit pointer setting (see
Terms and abbreviations
Selects the source for freely programmable fieldbus status
word bit 29
(02.24 FBA main sw
Bit pointer setting (see
Terms and abbreviations
Selects the source for freely programmable fieldbus status
word bit 30
(02.24 FBA main sw
Bit pointer setting (see
Terms and abbreviations
Selects the source for freely programmable fieldbus status
word bit 31
(02.24 FBA main sw
Bit pointer setting (see
Terms and abbreviations
Fieldbus adapter-specific settings.
Displays the type of the connected fieldbus adapter module.
0 = Fieldbus module is not found, or it is not properly
connected, or parameter
1 = FPBA-xx PROFIBUS-DP adapter module, 32 = FCAN-xx
CANopen adapter module, 37 = FDNA-xx DeviceNet adapter
module
Parameters
51.02...51.26
more information, see the User's Manual of the fieldbus
adapter module. Note that not all of these parameters are
necessarily visible.
...
See parameter
51.02 FBA
modesel.
modesel.
modesel.
modesel.
Terms and abbreviations
Terms and abbreviations
bit 28 SW B28).
on page 63). -
bit 29 SW B29).
on page 63). -
bit 30 SW B30).
on page 63). -
bit 31 SW B31).
on page 63). -
50.01 Fba enable
is set to Disable,
are adapter module-specific. For
par2.
Parameters 183
FbEq
0
1
2
is set to
on page
-
is set to
on page
-
-
...
-