No.
Name/Value
Supervision2
Supervision3
Const
Pointer
14.18
DIO5 conf
Output
Input
14.19
DIO5 out src
Brake cmd
Ready
Enabled
Started
Running
Alarm
Ext2 active
Fault
Fault(-1)
Ready relay
RunningRelay
Ref running
Charge ready
Neg speed
Zero speed
Above limit
At setpoint
Supervision1
Supervision2
Supervision3
Const
Pointer
14.22
DIO6 conf
Output
Input
14.23
DIO6 out src
Brake cmd
Ready
Enabled
Started
Running
Alarm
Description
Bit 1 of
06.13 Superv status
Bit 2 of
06.13 Superv status
Bit pointer setting (see
Terms and abbreviations
Selects whether DIO5 is used as a digital output or input.
DIO5 is used as a digital output.
DIO5 is used as a digital input.
Selects a drive signal to be connected to digital output DIO5
(when
14.18 DIO5 conf
03.16 Brake command
(see page 71).
Bit 0 of
06.01 Status word1
Bit 1 of
06.01 Status word1
Bit 2 of
06.01 Status word1
Bit 3 of
06.01 Status word1
Bit 7 of
06.01 Status word1
Bit 8 of
06.01 Status word1
Bit 10 of
06.01 Status word1
Bit 12 of
06.01 Status word1
Bit 2 of
06.02 Status word2
Bit 3 of
06.02 Status word2
Bit 4 of
06.02 Status word2
Bit 9 of
06.02 Status word2
Bit 0 of
06.03 Speed ctrl stat
Bit 1 of
06.03 Speed ctrl stat
Bit 2 of
06.03 Speed ctrl stat
Bit 3 of
06.03 Speed ctrl stat
Bit 0 of
06.13 Superv status
Bit 1 of
06.13 Superv status
Bit 2 of
06.13 Superv status
Bit pointer setting (see
Terms and abbreviations
Selects whether DIO6 is used as a digital output or input.
DIO6 is used as a digital output.
DIO6 is used as a digital input.
Selects a drive signal to be connected to digital output DIO6
(when
14.22 DIO6 conf
03.16 Brake command
(see page 71).
Bit 0 of
06.01 Status word1
Bit 1 of
06.01 Status word1
Bit 2 of
06.01 Status word1
Bit 3 of
06.01 Status word1
Bit 7 of
06.01 Status word1
(see page 76).
(see page 76).
is set to Output).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
(see page 74).
(see page 74).
(see page 74).
(see page 74).
(see page 75).
(see page 75).
(see page 75).
(see page 75).
(see page 76).
(see page 76).
(see page 76).
is set to Output).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
(see page 73).
Parameters 101
FbEq
1073808909
1073874445
on page 63). -
0
1
1073742608
1073743361
1073808897
1073874433
1073939969
1074202113
1074267649
1074398721
1074529793
1073874434
1073939970
1074005506
1074333186
1073743363
1073808899
1073874435
1073939971
1073743373
1073808909
1073874445
on page 63). -
0
1
1073742608
1073743361
1073808897
1073874433
1073939969
1074202113

Advertisement

Table of Contents
loading

Table of Contents