ABB ACS850 Firmware Manual page 184

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

184 Parameters
No.
Name/Value
51.27
FBA par refresh
Done
Refresh
51.28
Par table ver
0x0000 ... 0xFFFF
51.29
Drive type code
0 ... 65535
51.30
Mapping file ver
0 ... 65535
51.31
D2FBA comm sta
Idle
Exec.init
Time out
Conf.err
Off-line
On-line
Reset
51.32
FBA comm sw ver
51.33
FBA appl sw ver
Description
Validates any changed adapter module configuration
parameter settings. After refreshing, the value reverts
automatically to Done.
Note: This parameter cannot be changed while the drive is
running.
Refreshing done.
Refreshing.
Displays the parameter table revision of the fieldbus adapter
module mapping file stored in the memory of the drive.
In format xyz, where x = major revision number; y = minor
revision number; z = correction number.
Parameter table revision.
Displays the drive type code of the fieldbus adapter module
mapping file stored in the memory of the drive.
Drive type code of fieldbus adapter module mapping file.
Displays the fieldbus adapter module mapping file revision
stored in the memory of the drive in decimal format. Example:
1 = revision 1.
Mapping file revision.
Displays the status of the fieldbus adapter module
communication.
Adapter is not configured.
Adapter is initializing.
A timeout has occurred in the communication between the
adapter and the drive.
Adapter configuration error: The major or minor revision code
of the common program revision in the fieldbus adapter
module is not the revision required by the module (see
parameter
51.32 FBA comm sw
has failed more than three times.
Adapter is off-line.
Adapter is on-line.
Adapter is performing a hardware reset.
Displays the common program revision of the adapter module
in format axyz, where a = major revision number, xy = minor
revision numbers. z = correction letter.
Example: 190A = revision 1.90A.
Common program version of adapter module.
Displays the application program revision of the adapter
module in format axyz, where: a = major revision number, xy
= minor revision numbers, z = correction letter.
Example: 190A = revision 1.90A.
Application program revision of adapter module.
ver) or mapping file upload
FbEq
0
1
1 = 1
1 = 1
1 = 1
0
1
2
3
4
5
6
1 = 1
1 = 1

Advertisement

Table of Contents
loading

Table of Contents