Fba A Settings - ABB ACS880 Firmware Manual

Dc/dc converter control program
Hide thumbs Also See for ACS880:
Table of Contents

Advertisement

No.
Name/Value
Fast
Very fast
Monitoring
151

151 FBA A settings

151.01
FBA type
151.02
FBA Par2
0...65535
...
...
151.26
FBA Par26
0...65535
151.27
FBA par refresh
Done
Configure
151.28
Par table ver
0...65535
151.29
Drive type code
0...65535
151.30
Mapping file ver
0...65535
151.31
D2FBA comm sta
Idle
Exec.init
Time out
Conf.err
Description
Fast speed.
Very fast speed.
Low speed. Optimized for PC tool communication and
monitoring usage.
Fieldbus adapter A configuration.
Displays the type of the connected fieldbus adapter module.
0 = Module is not found or is not properly connected, or is
disabled by parameter
150.01 FBA A
32 = FCAN; 37 = FDNA; 101 = FCNA; 128 = FENA-11/21;
132 = PROFINET IO; 135 = FECA; 136 = FEPL;
485 = FSCA; 62944 = FSEA.
Note: All types of the fieldbus adapter modules are not
necessarily supported yet.
This parameter is read-only.
Parameters
151.02...151.26
For more information, see the documentation of the fieldbus
adapter module. Note that not all of these parameters are
necessarily used.
Fieldbus adapter configuration parameter.
...
See parameter
151.02 FBA
Fieldbus adapter configuration parameter.
Validates any changed fieldbus adapter module
configuration settings. After refreshing, the value reverts
automatically to Done.
Note: This parameter cannot be changed while the DC/DC
converter unit is running.
Refreshing done.
Refreshing.
Displays the parameter table revision of the fieldbus adapter
module mapping file stored in the memory.
In format axyz, where a = major revision number; xy = minor
revision number; z = correction number.
Parameter table revision of adapter module.
Displays the type code of the fieldbus adapter module
mapping file stored in the memory.
Type code of fieldbus adapter module mapping file.
Displays the fieldbus adapter module mapping file revision
stored in the memory of the DC/DC converter unit in
decimal format.
Example: 0x107 = revision 1.07.
Mapping file revision.
Displays the status of the fieldbus adapter module
communication.
Adapter is not configured.
Adapter is initializing.
A time-out has occurred in the communication between the
adapter and the DC/DC converter unit.
Adapter configuration error: the major or minor revision
code of the common program revision in the fieldbus
adapter module is not the revision required by the module
(see parameter
151.32 FBA comm SW
upload has failed more than three times.
Enable; 1 = FPBA;
are adapter module-specific.
Par2.
ver), or mapping file
Parameters 129
Def/FbEq16
1
2
3
-
-
1 = 1
...
-
1 = 1
Done
0
1
-
1 = 1
-
1 = 1
-
1 = 1
Idle
0
1
2
3