ABB ACS850 Firmware Manual page 68

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

68 Parameters
No.
Name/Value
Bit
Name
(continued)
9
Jogging 1
10
Jogging 2
11
Remote
cmd
12
Ramp out 0
13
Ramp hold
14
Ramp in 0
15
Ext1 / Ext2
16
Req startinh
17
Local ctl
18
FbLocal ref
19...27 Reserved
28
CW B28
29
CW B29
30
CW B30
31
CW B31
Description
Value Information
1
Activate Jogging 1. See section
0
Jogging 1 disabled.
1
Activate Jogging 2. See section
0
Jogging 2 disabled.
1
Fieldbus control enabled.
0
Fieldbus control disabled.
1
Force output of Ramp Function Generator to zero. The
drive ramps to a stop (current and DC voltage limits
are in force).
0
No action.
1
Halt ramping (Ramp Function Generator output held).
0
No action.
1
Force input of Ramp Function Generator to zero.
0
No action.
1
Switch to external control location EXT2.
0
Switch to external control location EXT1.
1
Activate start inhibit.
0
No start inhibit.
1
Request local control for Control Word. Used when the
drive is controlled from a PC tool or panel or local
fieldbus.
• Local fieldbus: Transfer to fieldbus local control
(control through fieldbus Control Word or
reference). Fieldbus steals the control.
• Panel or PC tool: Transfer to local control.
0
Request external control.
1
Request fieldbus local control.
0
No fieldbus local control.
Freely programmable control bits. See parameters
50.08...50.11
and the user manual of the fieldbus adapter.
FbEq
Jogging
on page 32.
Jogging
on page 32.
Log.
Par.
OR
10.07
OR
10.08
OR
12.01