188 Parameters
No.
Name/Value
57.13
Next ref1 mc grp
0
1...62
57.14
Nr ref1 mc grps
1...62
57.15
D2D com port
on-board
Slot 1
Slot 2
Slot 3
64

64 Load analyzer

64.01
PVL signal
Speed rpm
Speed %
Frequency
Current
Current %
Torque
Dc-voltage
Power inu
Power motor
Process act
Proc PID out
Pointer
Description
Specifies the next multicast group of drives the multicast
message is relayed to. See parameter
This parameter is effective only in the master or intermediate
followers (i.e. followers relaying the message to other
followers).
No group selected.
Next multicast group in the chain.
In the master drive, sets the total number of links (followers or
groups of followers) in the multicast message chain. See
parameter
57.11 Ref1 msg
Notes:
• This parameter has no effect if the drive is a follower.
• The master counts as a member of the chain if
acknowledgement from the last drive to the master is
desired.
Number of links in the multicast chain.
Defines the hardware to which the drive-to-drive link is
connected. In special cases (such as harsh operating
conditions), the galvanic isolation provided by the RS-485
interface of the FMBA module may make for more robust
communication than the standard drive-to-drive connection.
Connector X5 on the JCU Control Unit is used.
An FMBA module installed in JCU option slot 1 is used.
An FMBA module installed in JCU option slot 2 is used.
An FMBA module installed in JCU option slot 3 is used.
Peak value and amplitude logger settings. See also section
Load analyzer
on page 34.
Selects the signal to be monitored by the peak value logger.
The signal is filtered using the filtering time specified by
parameter
64.02 PVL filt time.
The peak value is stored, along with other pre-selected
signals at the time, into parameters 64.06...64.11.
Parameter
64.03 Reset loggers
logger and amplitude logger 2. The latest time the loggers
were reset is stored into parameter 64.13.
01.01 Motor speed rpm
01.02 Motor speed %
(see page 64).
01.03 Output frequency
01.04 Motor current
(see page 64).
01.05 Motor current %
(see page 64).
01.06 Motor torque
(see page 64).
01.07 Dc-voltage
(see page 64).
01.22 Power inu out
(see page 64).
01.23 Motor power
(see page 64).
04.03 Process act
(see page 72).
04.05 Process PID out
(see page 72).
Value pointer setting (see
63).
57.11 Ref1 msg type.
type.
resets both the peak value
(see page 64).
(see page 64).
Terms and abbreviations
FbEq
0
1 = 1
1 = 1
0
1
2
3
1073742081
1073742082
1073742083
1073742084
1073742085
1073742086
1073742087
1073742102
1073742103
1073742851
1073742853
on page
-