O Values - ABB ACS850 Firmware Manual

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

No.
Name/Value
01.29
Torq nom scale
01.30
Polepairs
01.31
Mech time const
01.32
Temp phase A
01.33
Temp phase B
01.34
Temp phase C
01.35
Saved energy
01.36
Saved amount
01.37
Saved CO2
02
02 I/O values
02.01
DI status
02.02
RO status
02.03
DIO status
02.04
AI1
02.05
AI1 scaled
02.06
AI2
02.07
AI2 scaled
02.08
AI3
02.09
AI3 scaled
02.10
AI4
Description
Nominal torque which corresponds to 100%.
Note: This value is copied from parameter
torque
if entered. Otherwise the value is calculated.
Calculated number of pole pairs in the motor.
Mechanical time constant of the drive and the machinery as
determined by the speed controller autotune function.
See parameter group
23 Speed ctrl
Measured temperature of phase U power stage in degrees
Celsius.
Measured temperature of phase V power stage in degrees
Celsius.
Measured temperature of phase W power stage in degrees
Celsius.
Energy saved in kWh compared to direct-on-line motor
connection.
See parameter group
45 Energy optimising
Monetary savings compared to direct-on-line motor
connection. This value is a multiplication of parameters
Saved energy
and
45.02 Energy
See parameter group
45 Energy optimising
Reduction in CO
emissions in metric tons compared to
2
direct-on-line motor connection. This value is a calculated by
multiplying saved energy in megawatt-hours by 0.5 metric
tons/MWh.
See parameter group
45 Energy optimising
Input and output signals.
Status of digital inputs DI6...DI1. Example: 000001 = DI1 is
on, DI2...DI6 are off.
Note: If an FIO-21 extension is installed, the status of its
digital input is indicated by parameter
Status of relay outputs RO5...RO1. Example: 00001 = RO1
is energized, RO2...RO5 are de-energized.
Status of digital input/outputs DIO10...DIO1. Example:
0000001001 = DIO1 and DIO4 are on, remainder are off.
Note: If an FIO-21 extension is installed, the status of its
digital input is also indicated by this parameter.
Value of analogue input AI1 in V or mA. Input type is selected
with jumper J1 on the JCU Control Unit.
Scaled value of analogue input AI1. See parameters
AI1 max scale
and
13.05 AI1 min
Value of analogue input AI2 in V or mA. Input type is selected
with jumper J2 on the JCU Control Unit.
Scaled value of analogue input AI2. See parameters
AI2 max scale
and
13.10 AI2 min
Value of analogue input AI3 in V or mA. For input type
information, see the extension module manual.
Scaled value of analogue input AI3. See parameters
AI3 max scale
and
13.15 AI3 min
Value of analogue input AI4 in V or mA. For input type
information, see the extension module manual.
99.12 Mot nom
on page 128.
on page 179.
01.35
tariff1.
on page 179.
on page 179.
02.03 DIO
status.
13.04
scale.
13.09
scale.
13.14
scale.
Parameters 65
FbEq
1000 =
1 N•m
1 = 1
1000 = 1 s
10 = 1 °C
10 = 1 °C
10 = 1 °C
1 = 1 kWh
1 = 1
1 = 1 metric
ton
-
-
-
1000 = 1 unit
1000 = 1 unit
1000 = 1 unit
1000 = 1 unit
1000 = 1 unit
1000 = 1 unit
1000 = 1 unit