Parameters

What this chapter contains

The chapter describes the parameters, including actual signals, of the control
program.
Note: By default, a selective list of parameters is shown by the drive panel or
DriveStudio. All parameters can be displayed by setting parameter
sel
to
Load
long.

Terms and abbreviations

Term
Actual signal
Bit pointer setting
FbEq
p.u.
Value pointer setting
Definition
Type of parameter that is the result of a measurement or calculation by
the drive. Actual signals can be monitored, but not adjusted, by the user.
Parameter groups 1...9 typically contain actual signals.
A parameter setting that points to the value of a bit in another parameter
(usually an actual signal), or that can be fixed to 0 (FALSE) or 1 (TRUE).
When adjusting a bit pointer setting on the optional control panel, "Const"
is selected in order to fix the value to 0 (displayed as "C.False") or 1
("C.True"). "Pointer" is selected to define a source from another
parameter.
A pointer value is given in the format P.xx.yy.zz, where xx = parameter
group, yy = parameter index, zz = bit number.
Pointing to a nonexisting bit will be interpreted as 0 (FALSE).
In addition to the "Const" and "Pointer" selections, bit pointer settings may
also have other pre-selected settings.
Fieldbus equivalent. The scaling between the value shown on the panel
and the integer used in serial communication.
Per unit
A parameter that points to the value of another actual signal or
parameter.
A pointer value is given in the format P.xx.yy, where xx = parameter
group, yy = parameter index.
Parameters 63
6
16.15 Menu set