ABB ACS850 Firmware Manual page 189

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

No.
Name/Value
64.02
PVL filt time
0.00 ... 120.00 s
64.03
Reset loggers
Const
Pointer
64.04
AL signal
Speed rpm
Speed %
Frequency
Current
Current %
Torque
Dc-voltage
Power inu
Power motor
Process act
Proc PID out
Pointer
64.05
AL signal base
0.00 ... 32768.00
64.06
PVL peak value1
-32768.00 ...
32768.00
64.07
Date of peak
01.01.80 ...
64.08
Time of peak
00:00:00 ...
23:59:59
Description
Peak value logger filtering time. See parameter
signal.
Peak value logger filtering time.
Selects the signal to reset the peak value logger and
amplitude logger 2. (Amplitude logger 1 cannot be reset.)
Bit pointer setting (see
Terms and abbreviations
Selects the signal to be monitored by amplitude logger 2. The
signal is sampled at 200 ms intervals when the drive is
running.
The results are displayed by parameters 64.24...64.33. Each
parameter represents an amplitude range, and shows what
portion of the samples fall within that range.
The signal value corresponding to 100% is defined by
parameter
64.05 AL signal
Parameter
64.03 Reset loggers
logger and amplitude logger 2. The latest time the loggers
were reset is stored into parameter 64.13.
Note: Amplitude logger 1 is fixed to monitor motor current
(01.04 Motor
current). The results are displayed by
parameters 64.14...64.23. 100% of the signal value
corresponds to the nominal output current of the drive (see
the appropriate Hardware Manual).
01.01 Motor speed rpm
01.02 Motor speed %
(see page 64).
01.03 Output frequency
01.04 Motor current
(see page 64).
01.05 Motor current %
(see page 64).
01.06 Motor torque
(see page 64).
01.07 Dc-voltage
(see page 64).
01.22 Power inu out
(see page 64).
01.23 Motor power
(see page 64).
04.03 Process act
(see page 72).
04.05 Process PID out
(see page 72).
Value pointer setting (see
63).
Defines the signal value that corresponds to 100% amplitude.
Signal value corresponding to 100%.
Peak value recorded by the peak value logger.
Peak value.
The date on which the peak value was recorded.
Peak occurrence date (dd.mm.yy).
The time at which the peak value was recorded.
Peak occurrence time.
base.
resets both the peak value
(see page 64).
(see page 64).
Terms and abbreviations
Parameters 189
FbEq
64.01 PVL
100 = 1 s
on page 63). -
1073742081
1073742082
1073742083
1073742084
1073742085
1073742086
1073742087
1073742102
1073742103
1073742851
1073742853
on page
-
100 = 1
100 = 1
1 = 1 d