Parameter Listing; Actual Values - ABB ACS850 Firmware Manual

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

64 Parameters

Parameter listing

No.
Name/Value
01

01 Actual values

01.01
Motor speed rpm
01.02
Motor speed %
01.03
Output frequency
01.04
Motor current
01.05
Motor current %
01.06
Motor torque
01.07
Dc-voltage
01.08
Encoder1 speed
01.09
Encoder1 pos
01.10
Encoder2 speed
01.11
Encoder2 pos
01.12
Pos act
01.13
Pos 2nd enc
01.14
Motor speed est
01.15
Temp inverter
01.16
Temp brk chopper
01.17
Motor temp1
01.18
Motor temp2
01.19
Used supply volt
01.20
Brake res load
01.21
Cpu usage
01.22
Power inu out
01.23
Motor power
01.24
kWh inverter
01.25
kWh supply
01.26
On-time counter
01.27
Run-time counter
01.28
Fan on-time
Description
Basic signals for monitoring of the drive.
Filtered actual speed in rpm. The used speed feedback is
defined by parameter
19.02 Speed fb
constant can be adjusted using parameter
filt.
Actual speed in percent of the motor synchronous speed.
Estimated drive output frequency in Hz.
Measured motor current in A.
Motor current in percent of the nominal motor current.
Motor torque in percent of the nominal motor torque. See also
parameter
01.29 Torq nom
Measured intermediate circuit voltage.
Encoder 1 speed in rpm.
Actual position of encoder 1 within one revolution.
Encoder 2 speed in rpm.
Actual position of encoder 2 within one revolution.
Actual position of encoder 1 in revolutions.
Scaled actual position of encoder 2 in revolutions.
Estimated motor speed in rpm.
Estimated temperature of drive heatsink in degrees Celsius.
Brake chopper IGBT temperature in degrees Celsius.
Measured temperature of motor 1 in degrees Celsius.
Measured temperature of motor 2 in degrees Celsius.
Supply voltage as determined by the program.
Estimated temperature of the braking resistor. The value is
given in percent of the temperature the resistor reaches when
loaded with the power defined by parameter
max
cnt.
Microprocessor load in percent.
Drive output power in kW or hp, depending on setting of
parameter
16.17 Power
Measured motor power in kW or hp, depending on setting of
parameter
16.17 Power
Amount of energy that has passed through the drive (in either
direction) in kilowatt-hours.
Amount of energy that the drive has taken from the AC supply
in kilowatt-hours.
On-time counter. The counter runs when the drive is
powered. Can be reset using the DriveStudio PC tool.
Motor run-time counter. The counter runs when the inverter
modulates. Can be reset using the DriveStudio PC tool.
Running time of the drive cooling fan. Can be reset by
entering 0.
sel. The filter time
19.03 MotorSpeed
scale.
48.04 Br power
unit.
unit.
FbEq
100 = 1 rpm
100 = 1%
100 = 1 Hz
100 = 1 A
10 = 1%
10 = 1%
100 = 1 V
100 = 1 rpm
100000000 =
1 rev
100 = 1 rpm
100000000 =
1 rev
1000 = 1 rev
1000 = 1 rev
100 = 1 rpm
10 = 1 °C
10 = 1 °C
10 = 1 °C
10 = 1 °C
10 = 1 V
1 = 1 °C
1 = 1%
100 = 1 kW
or hp
100 = 1 kW
or hp
1 = 1 kWh
1 = 1 kWh
1 = 1 h
1 = 1 h
1 = 1 h

Advertisement

Table of Contents
loading

Table of Contents