186 Parameters
No.
Name/Value
Drive name
Drive type
56.05
Signal2 mode
Disabled
Normal
Bar
Drive name
Drive type
56.06
Signal3 mode
Disabled
Normal
Bar
Drive name
Drive type
57
57 D2D
communication
57.01
Link mode
Disabled
Follower
Master
57.02
Comm loss func
No
Alarm
Fault
57.03
Node address
1 ... 62
57.04
Follower mask 1
Description
Shows the drive name. (The drive name can be set using the
DriveStudio PC tool.)
Shows the drive type.
Defines the way the signal selected by parameter
Signal2 param
is displayed on the optional control panel.
Signal not displayed. Any other signals that are not disabled
are shown together with their respective signal name.
Shows the signal as a numerical value followed by unit.
Shows the signal as a horizontal bar.
Shows the drive name. (The drive name can be set using the
DriveStudio PC tool.)
Shows the drive type.
Defines the way the signal selected by parameter
Signal3 param
is displayed on the optional control panel.
Signal not displayed. Any other signals that are not disabled
are shown together with their respective signal name.
Shows the signal as a numerical value followed by unit.
Shows the signal as a horizontal bar.
Shows the drive name. (The drive name can be set using the
DriveStudio PC tool.)
Shows the drive type.
Configuration of drive-to-drive communication. See also
section
Drive-to-drive link
Activates the drive-to-drive connection.
Drive-to-drive connection disabled.
The drive is a follower on the drive-to-drive link.
The drive is the master on the drive-to-drive link. Only one
drive can be the master at a time.
Selects how the drive acts when an erroneous drive-to-drive
configuration or a communication break is detected.
Protection not active.
The drive generates an alarm.
The drive trips on a fault.
Sets the node address for a follower drive. Each follower
must have a dedicated node address.
Note: If the drive is set to be the master on the drive-to-drive
link, this parameter has no effect (the master is automatically
assigned node address 0).
Node address.
On the master drive, selects the followers to be polled. If no
response is received from a polled follower, the action
selected by parameter
57.02 Comm loss func
The least significant bit represents follower with node address
1, while the most significant bit represents follower 31. When
a bit is set to 1, the corresponding node address is polled. For
example, followers 1 and 2 are polled when this parameter is
set to the value of 0x3.
on page 31.
is taken.
FbEq
2
3
56.02
-1
0
1
2
3
56.03
-1
0
1
2
3
0
1
2
0
1
2
1 = 1