ABB ACS850 Firmware Manual page 246

Standard control program
Hide thumbs Also See for ACS850:
Table of Contents

Advertisement

246 Fieldbus control
Parameter
51.30 Mapping file
ver
51.31 D2FBA comm
sta
51.32 FBA comm
sw ver
51.33 FBA appl sw
ver
Note: In the User's Manual of the fieldbus adapter module, the parameter group number is 1
or A for parameters
TRANSMITTED DATA SELECTION (see also page 185)
52.01 FBA data in1
...
52.12 FBA data
in12
53.01 FBA data out1
...
53.12 FBA data
out12
Note: In the User's Manual of the fieldbus adapter module, the parameter group number is 3
or C for parameters
After the module configuration parameters have been set, the drive control
parameters (see section
adjusted when necessary.
The new settings will take effect when the drive is powered up the next time (before
powering off the drive, wait at least 1 minute), or when parameter
refresh
is activated.
Setting for
fieldbus control
51.01...51.26.
4...6
14...16
101...9999
1...3
11...13
1001...9999
52.01...52.12
and 2 or B for parameters 53.01...53.12.
Drive control parameters
Function/Information
Displays the fieldbus adapter module
mapping file revision stored in the memory
of the drive.
Displays the status of the fieldbus adapter
module communication.
Displays the common program revision of
the adapter module.
Displays the application program revision of
the adapter module.
Defines the data transmitted from drive to
fieldbus controller.
Note: If the selected data is 32 bits long,
two parameters are reserved for the
transmission.
Defines the data transmitted from fieldbus
controller to drive.
Note: If the selected data is 32 bits long,
two parameters are reserved for the
transmission.
below) must be checked and
51.27 FBA par