Figure 23. Synchronous, Non-Multiplexed Address - 32-Bit Single-Word Memory Read Timing - DDC Total-AceXtreme MIL-STD-1553 Design Manual

Ultra-small, ultra-low power single package solution
Table of Contents

Advertisement

tCLK
HOST_CLK
nSELECT
nDATA_STRB
CPU_ADDR
MEM_nREG
RD_nWR
CPU_WORD_EN[1:0]
CPU_DATA
nDATA_RDY
CPU_nSTOP
CPU_nLAST
Figure 23. Synchronous, Non-Multiplexed Address - 32-bit Single-Word Memory Read
Figure 23 Notes:
1. When nSELECT is asserted (low), the Total-AceXtreme® is selected for this
data transfer. nSELECT must be asserted through the full transfer cycle, and
de-asserted high at the end of the transfer.
2. The CPU_WORD_EN[1:0] inputs are used to specify which 16-bit data
memory words are valid for this transfer. If either or both these bits is '0', then
the corresponding 16-bit word(s) will return a value of '0000'. These inputs
should be tied high if unused.
3. Unless the Total-AceXtreme command FIFO is full, CPU_nSTOP will not be
asserted for memory accesses, and will remain high.
Data Device Corporation
www.ddc-web.com
tWait
tCS
tSH
tSS
tAS
Address
tAS
tAS
tAS
Timing
63
H O S T I N T E R F A C E
tCH
tAH
tAH
tAH
tAH
tOH
tDD
tOHZ
Data
tRDD
tRDD
tSHC
DS-BU-67301B-G
1/14

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Total-acextreme bu-67301b

Table of Contents