nSELECT
nDATA_STRB
CPU_ADDR
MEM_nREG
CPU_WORD_EN[1:0]
MSW_nLSW
RD_nWR
CPU_DATA
nDATA_RDY

Figure 13. Asynchronous Non-Multiplexed Address 16-bit Read Timing

Figure 13 Notes:
1. When nSELECT is asserted (low), the Total-AceXtreme® is selected for this
data transfer. nSELECT must be asserted through the full transfer cycle. In
Asynchronous mode, nSELECT may be kept low for consecutive transactions
by the Total-AceXtreme.
2. For 16-bit accesses, CPU_WORD_EN[1:0] must be '11' through the full
transfer cycle.
3. For register accesses, the value of CPU_WORD_EN[1:0] must be '11'.
Data Device Corporation
www.ddc-web.com
tSS
tAS
tAS
tAS
tAS
tAS
Data A
tDD
tWait
45
H O S T I N T E R F A C E
Address
tAS
tOH
tOHZ
tRDD
tWait
tSH
tAH
tAH
tAH
tAH
tAH
tOH
tOHZ
Data B
tDD
tRDD