11
TOTAL-ACEXTREME® SIGNALS

11.1 Signal Descriptions and Pinout by Functional Groups

Signal Name
BALL
DISABLE_BC (I)
C14
DISABLE_MULTI_RT (I)
D14
PCI_nCPU (I)
C11
nRTBOOT (I)
D13
nPOR
C10
PLL_LOCKED
Data Device Corporation
www.ddc-web.com

Table 15. Protocol Configuration

Pullup/
Pulldown
50k
When '1', indicates that the Total-AceXtreme cannot operate in BC mode (i.e.
Pulldown
BC operation is disabled).
When '0', indicates that the Total-AceXtreme can operate in BC mode
provided that it isn't an RT-ONLY device.
50k
When '1', indicates that the Total-AceXtreme cannot operate in Multi-RT
Pulldown
mode (i.e. Limited to one RT-Address).
When '0', indicates that the Total-AceXtreme can operate in Multi-RT mode.
50k
When '1', indicates that the PCI interface is active. When '0', indicates that
Pulldown
the CPU Interface is active.
50k Pullup
If nRTBOOT is connected to logic "0", the Total-AceXtreme will initialize in
RT mode with the Busy status word bit set following power turn-on. If
nRTBOOT is hardwired to logic "1", the Total-AceXtreme will initialize in
either Idle mode (for an RT-only part), or BC mode (for a BC/RT/MT part).
None
Power-on Reset. Asserting nPOR low resets all Total-AceXtreme logic, along
with the PLL that generates the internal 160 MHz clock. Following the low-to-
high transition of nPOR, if enabled (by DISABLE_BIST = '0'), the Total-
AceXtreme will initiate its internal built-in self-test (BIST). The host processor
should not attempt to access the Total-AceXtreme registers or memory until
at least 1 ms after the low-to-high transition of nPOR. Following nPOR being
asserted high, the host processor must wait a minimum of 1 ms if
DISABLE_BIST = '0', or 500 μs if DISABLE_BIST ='1' before accessing
memory or registers.
A13
None
PLL Locked output. Indicates that the output from the PLL providing the
internal 160 MHz clock is operational. Immediately following power turn-on,
PLL_LOCKED will assert low, and will remain low while nPOR is asserted
low. Assuming correct operation of the PLL, PLL_LOCKED will transition
from '0' to '1' following a maximum of 100 µs after nPOR goes high.
Description
108
DS-BU-67301B-G
1/14