Problem: Starter Motor Inoperative - Jeep J-10 Series 1982 Technical & Service Manual

Table of Contents

Advertisement

BATTERIES
1D-7
BATTERY DIAGNOSIS AND REPAIR SIMPLIFICATION (DARS) CHART
Note: Refer to Chapter A — General Information for details on how to use this DARS chart.
PROBLEM: STARTER MOTOR INOPERATIVE
Chart 1
RESULT
STEP
SEQUENCE
©
o
i DAMAGED
CASE
OR
COVER
CHECK ELECTROLYTE LEVEL AND
TEST SPECIFIC GRAVITY IN EACH
CELL AND RECORD.
• LOOSE
ALTERNATOR
DRIVE BELT
DEFECTIVE
CABLE
^
REPAIR OR REPLACE
IF NECESSARY
ELECTROLYTE LEVEL TOO LOW FOR SPECIFIC GRAVITY
TEST-ADD WATER. CHARGE BATTERY FOR 10 MIN.
AT 20 AMP RATE.
TEST SPECIFIC GRAVITY
OK
AVERAGE SPECIFIC GRAVITY 1.225 OR MORE
CELLS ARE EQUAL WITHIN 0.050 (50 POINTS)
r<^H
EPLACE
BATTERY
AVERAGE SPECIFIC GRAVITY 1.225 OR MORE
BUT CELLS VARY 0.050 (50 POINTS) OR MORE
CKC
AVERAGE SPECIFIC GRAVITY BELOW 1.225
CONNECT BATTERY CHARGER AND VOLTMETER
CHARGE BATTERY FOR 3 MINUTES AT 40 AMP RATE
AT THE END OF 3 MINUTES OBSERVE VOLTMETER
WHILE CHARGER IS STILL CHARGING
OK
VOLTAGE IS 15.5 VOLTS OR LESS
>s
VOLTAGE ABOVE 155 VOLTS
SLOW CHARGE
BATTERY AT
3 TO 4 AMPS
FOR 48 TO
72 HOURS
©
©
o
©
70060A