(3) Remove float and bend float arm as necessary to
adjust. Refer to Specifications.
(4) Visually check float alignment after adjust
ment.
RETAINER
NEEDLE
TOE OF
FLOAT
(TOP VIEW)
FLOAT ARM
90717
Fig. U-51
Model 2SE Carburetor—Float Adjustment
Accelerator Pump Adjustment
The pump adjustment should not be changed from the
original factory assembly adjustment unless measure
ment indicates it is not within the specification. The
pump lever is hardened steel and bending it is very
difficult. Do not attempt to bend unless absolutely
necessary.
(1) With throttle valves completely closed and fast
idle adjustment screw off fast idle cam step, measure
distance from air horn casting to top of pump stem.
Refer to Specifications.
(2) If adjustment is necessary, remove pump lever
retaining screw and lever by rotating from pump rod.
CAUTION: Do not bend lever sideways or twist it.
(3) Place lever in soft jawed vise and bend end of
lever as necessary to obtain correct dimension.
(4) Install pump lever and retaining screw.
(5) Check adjustment and if correct tighten retain
ing screw securely.
(6) Open and close throttle valves to test linkage for
freedom of movement and lever for correct alignment.
Fist Idle Adjustment
(1) Position fast idle adjustment screw on highest
fast idle cam step.
(2) Turn fast idle adjustment screw in or out the
specified number of turns. Refer to Specifications.
Choke Coil Lever Adjustment
Do not remove the rivets and retainers securing the
choke cover and coil assembly unless it is necessary to
inspect the choke coil lever adjustment. If the rivets and
cover are removed, a choke cover retainer kit is required
for assembly.
(1) Remove rivets, retainers and choke cover and
coil assembly following instructions contained in choke
cover retainer kit.
(2) Position fast idle adjustment screw on highest
fast idle cam step.
(3) Push on intermediate choke lever and close
choke valve.
(4) Insert specified plug gauge in hole adjacent to
coil lever (see Specifications). Edge of lever should
barely contact plug gauge (fig. 1J-52).
(5) Bend intermediate choke rod with Adjusting
Wrench J-28692 to adjust clearance between lever and
plug gauge (fig. 1J-52).
INTERMEDIATE
CHOKE ROD
FAST IDLE
SCREW
^ ^
INTERMEDIATE
CHOKE LEVER
90718
Fig. U-52 Model 2SE Carburetor—Choke Coll Lever Adjustment
Fast Idle Cam Position Adjustment
The choke coil lever adjustment must be correct and
the fast idle adjustment must be completed before pro
ceeding (fig. 1J-53).
(1) Rotate degree scale of Carburetor Choke Angle
Gauge J-26701-A to position zero degree mark opposite
pointer.
(2) With choke valve completely closed, position
magnet squarely on top of choke valve. Rotate bubble
until it is centered.
(3) Rotate degree scale until degree mark specified
for adjustment is opposite pointer. Refer to
Specifications.
(4) Position fast idle screw on second cam step adja
cent to rise of high step.
(5) Close choke valve by pushing on intermediate
choke lever.
(6) Push vacuum break lever toward open choke
position until lever is against rear tang on choke lever.