Inverter; 4.10 Machine Function Speeds; Machine Safety System Override (Msso) - JLG E400A Narrow Operation And Safety Manual

Table of Contents

Advertisement

4.9

INVERTER

The inverter converts 48 VDC to 110 VAC to allow operation of
power tools from the machine's batteries.
• The inverter is operational when the emergency stop switch is
pulled out.
• The machine and inverter can be operated at the same time.
• The inverter will shut off at approximately 42 VDC and stay off
until the emergency stop switch is recycled. It will operate
again until voltage drops to 42 VDC.
• The machine will operate down to 36 VDC.
• The inverter will shut down if the high temperature light indi-
cated overheating. It will automatically turn back on when
cooled.
• The overload light indicates an output wiring short circuit or a
load that is too large for the rating of the inverter.

4.10 MACHINE FUNCTION SPEEDS

The Function Speed Control affects the speed of boom functions
Lower Lift, Telescope, and Rotate. Turn the control clockwise to
increase function speed or counterclockwise to decrease func-
tion speed. When in the counterclockwise maximum position, all
functions are placed in creep speed.
3121716
SECTION 4 - MACHINE OPERATION
4.11 MACHINE SAFETY SYSTEM OVERRIDE (MSSO)(CE
ONLY)
The Machine Safety System Override (MSSO) is
used to override function controls for Emergency
Platform Retrieval only. Refer to Section 5.7,
Machine Safety System Override (MSSO)(CE
Only)for operating procedures.
4-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E400ajpE400ajp narrowM400ajpM400ajp narrow

Table of Contents