5.5
Description
Access

EDM Settings

FlexLine plus, Settings
EDM Settings
The settings on this screen define the active EDM, Electronic Distance Measurement.
Different settings for measurements are available with Non-Prism (NP) and Prism (P)
EDM modes.
1.
Select
Settings from the Main Menu.
2.
Select
EDM from the Settings Menu.
Field
Description
EDM Mode
Prism
Non-Prism
Tape
Target
Round (GPR)
Mini (GMP)
Mini0
(GMP111-0)
Jp Mini
(SMP222)
360° (GRZ4)
360°Mini(GR
Z101)
Tape (GZM)
360°
(MPR122)
None
User 1 /
User 2
Atmos
To enter atmospheric data ppm.
Ind.PPM
To enter an individual ppm value.
Scale
To enter projection scale details.
Signal
To view EDM Signal reflection value.
Freq.
To view the EDM frequency.
For distance measurements using prisms.
For distance measurements without prisms.
For distance measurements using Retro reflective
targets (3 mm + 2 ppm).
Standard prism GPR121/GPR111
26
9
1
48
Leica Const.: 0.0 mm
GMP111
30
40
Leica Const.: +17.5 mm
GMP111-0
Leica Const.: 0.0 mm
Miniprism
Leica Const.: +34.4 mm
GRZ4/GRZ122
Leica Const.: +23.1 mm
GRZ101
Leica Const.: +30.0 mm
Leica Const.: +34.4 mm
MPR122
Leica Const.: +28.1 mm
Without prism
Leica Const.: +34.4 mm
For any prism modes, the user can define two of their
own prisms.
Constants can be entered in mm in either Leica Const.
or Abs. Const.. For example: