Remove 2 E-rings and then 2 gears.
(9)
Remove 2 screws to take off the new toner
transport motor.
Note:
Pay attention to the size (length) of the
screws. If incorrect ones are used, the motor
could be damaged.
4.8.6

Toner recycle unit

(1)
Take off the toner cartridge drive unit.
(
P.4-69 "4.8.1 Toner cartridge drive unit")
(2)
Remove 2 screws to take off the left inner
cover.
(3)
Disconnect 1 connector, remove 2 screws,
and then take off the toner recycle unit.
Notes:
1. Be extremely careful when handling this
unit because toner may spill out from the
joint with the toner recycle unit, cleaner
unit and developer unit.
2. Install the window of the shutter section
on the toner recycle unit so that it
matches with the protrusion of the
developer unit.
3. Be careful to allow as little vibration as
possible to the unit when installing and
removing the toner recycle unit. Vibration
could cause stains on the image after
assembling, especially when the
remaining toner amount in the cartridge is
small.
e-STUDIO556/656/756/856(Ver03)
DISASSEMBLY AND REPLACEMENT
Gear
Gear
Connector
© 2012 TOSHIBA TEC CORPORATION All rights reserved
4 - 72
New toner transport motor
Fig. 4-203
Toner recycle unit
Fig. 4-204
Protrusion
Fig. 4-205