8.4.21

Uneven light distribution

Defective area
Original glass
Main charger
Discharge LED
Scanner
Exposure lamp
e-STUDIO556/656/756/856(Ver03)
ERROR CODE AND TROUBLESHOOTING
Fig. 8-21
Step
Check items
1
Is the original glass dirty?
2
Are the needle electrode, main
charger grid and main charger case
dirty?
3
Is the discharge LED dirty?
4
Is any of the discharge LEDs off?
5
Are the reflector, exposure lamp,
mirrors, lens, and original glass
(especially the position of shading
correction plate) dirty?
6
Is the exposure lamp discolored or
degraded?
8 - 242
Prescription
Clean the original glass.
Clean or replace them.
Clean the discharge LED.
Replace the discharge LED.
Clean them.
Replace the exposure lamp.