Measurement At Replacement Of High-Voltage Transformer - Toshiba e-STUDIO556 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO556:
Table of Contents

Advertisement

6.8

Measurement at Replacement of High-Voltage Transformer

The high-voltage transformer does not need to be adjusted, however, when you check each value of
the main charger bias and the developer bias, it needs to be measured.
Note:
When carrying out the operation, be careful not to touch the electronic section because it is high
voltage.
6.8.1
Measurement
[ 1 ] Preparation
Items to check
Process Unit
Digital
Function switch
Tester
Full-scale (range)
Remarks
How to turn ON the power
[ 2 ] Installing Jig
(1)
Put in the door switch jig and slide it down.
(2)
Rotate the jig counterclockwise by 90 degrees.
Door switch jig
e-STUDIO556/656/756/856(Ver03)
ADJUSTMENT
Main Charger
Take off from the equipment
Use a digital tester with an input resistance of 10 MΩ (RMS value) or higher.
Attach the door switch jig and start with the adjustment mode [05] while the
front cover opened.
Fig. 6-24
6 - 42
Developer Bias
Remove the connector of the auto
toner sensor, and release the
developer unit from the drum.
DC
1000 V