Notes:
If LED 3 does not light, follow the procedure
below.
1. Tighten 2 prism vertical fixing screws
aligning with the forth mark-off line from
the top.
2. Loosen the 2 prism horizontal adjustment
screws.
3. Slide the prism horizontally. When the
prism comes to the proper adjustment
position, LED 3 on the RADF board lights.
At this position, tighten 2 prism horizontal
adjustment screws.
(7)
Perform the automatic adjustment (05-3210).
Note:
After the manual adjustment is performed, be sure to do the automatic one.
(8)
Turn the power OFF and install the cover.
e-STUDIO556/656/756/856(Ver03)
ADJUSTMENT
© 2012 TOSHIBA TEC CORPORATION All rights reserved