[8022] Authentication Failure
Classification
Network error
Check item
Setting
[8023] Can not contact Authentication Server/Switch
Classification
Network error
Check item
Setting
[8024] Certificate verification Failure
Classification
Network error
Check item
Setting
[8031] IKEv1 certification failed
Classification
Network error
Check item
Setting
[8032] IKEv1 wrong proposal choosen
Classification
Network error
Check item
Setting
e-STUDIO556/656/756/856(Ver03)
ERROR CODE AND TROUBLESHOOTING
Failed in 802.1X authentication.
Check the user credential.
Failed in connection to authentication server and switch.
Check connectivity to switch or server.
Failed in verification of certificate.
Check if a valid certificate is installed.
Ipsec error for ikev1 certification failed
Check
1. CA and user certificate in both MFP and remote peer - certificate
timestamp and IPsec Certificate template should be valid.
2. CRL DP server name is mapped in MFP's host table or DNS entry.
3. Certificate against CRL.
Ipsec error for wrong proposal choosen
Check the IKEv1 IPsec proposal parameters (like encryption/authentication
algorithms, DH group, authentication methods) in MFP and peer machine.