(4)
Remove 2 screws and take off the stay.
(5)
Disconnect each connector, remove each
screw and take off the thermistor and
thermostat.
Notes:
1. When installing the thermostats, be
careful not to deform the thermostats and
their brackets.
2. Adjust the gap between each thermostat
and the fuser roller to be 2.0-2.5 mm.
3. When installing, make sure that the
thermistor is in touch with the fuser roller.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
Screw
Fig. 4-287
Thermistor
Thermostat
Screw
Fig. 4-288
2.0~2.5mm
2.0~2.5mm
Heat roller
Fig. 4-289
4 - 103
Stay
Screw
Thermistor
Screw
Screw
Thermostat
e-STUDIO556/656/756/856(Ver03)