(4)
Remove 1 screw and take off the ground leaf
spring.
(5)
Remove 1 screw (white arrow) and take off
the bracket.
Note:
Install the bracket with its indicator pointed to
its original position.
(6)
Disconnect 1 connector and remove 1 screw
to take off the bypass paper size detection
sensor.
Note:
Pay attention to the following things when
setting up the bypass feed roller and pickup
roller.
-
Put the clip in the groove of the shaft
completely.
-
Make sure there is no adhesion of oil
and such on the timing belt, pulley and
roller.
-
Be careful not to install the bypass
pickup roller and feed roller in a wrong
direction.
-
Install the feed roller for the one-way
clutch to come to the rear side.
© 2012 TOSHIBA TEC CORPORATION All rights reserved
Bracket
Pointer
Fig. 4-121
Bypass paper size detection sensor
Fig. 4-122
Feed roller
Feeding direction
Separation roller
Fig. 4-123
4 - 43
Screw
Earth plate spring
Connector
Screw
Pickup roller